Purpose: To propose a standard measuring protocol for type B aortic dissections so as to improve comparability between studies reporting aortic dimensions.

Methods: Fifteen computed tomography (CT) scans of type B aortic dissections were measured with a standard protocol by 2 independent observers using postprocessing software. The following parameters were assessed: true, false, and total lumen diameter; true and false lumen volume; and entry tear size, location, and number. Diameters were measured in a perpendicular plane at 2, 10, and 20 cm from the left subclavian artery and 5 cm from the most distal renal artery. True lumen volume was assessed from the left subclavian artery to the aortic bifurcation, while the false lumen volume was from the start to end up to the aortic bifurcation. Entry tear location was assessed in relation to the left subclavian artery. Intra- and interobserver repeatability and agreement were evaluated using the Bland-Altman method, an a priori set of acceptable differences, and Lin's concordance correlation coefficient (LCCC).

Results: Intra- and interobserver mean differences for aortic diameter and true and false lumen volumes were generally within the limits of agreement and the a priori differences; the LCCC showed excellent agreement. Entry tear location, size, and number were difficult to measure in a repeatable manner, with inconsistent correlation coefficients, especially between the 2 observers.

Conclusion: This protocol showed acceptable repeatability for aortic diameter and aortic volume measurements. Assessment of entry tears proved challenging and associated with less favorable results. Additionally, investigators are urged to be more transparent regarding the measurement methodology used in studies describing aortic dimensions.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1526602816642591DOI Listing

Publication Analysis

Top Keywords

type aortic
12
aortic dissections
12
true false
12
false lumen
12
lumen volume
12
entry tear
12
left subclavian
12
subclavian artery
12
aortic
10
computed tomography
8

Similar Publications

The patient an 85-year-old female resided in a care facility where she maintained an independent daily activity level. She was discovered hunched over a table in her room, displaying reduced responsiveness and prompting an emergency call. Initially, her blood pressure was within 60 mmHg, and she was transported by ambulance to our hospital.

View Article and Find Full Text PDF

The outcomes of cardiac surgery in patients with hematologic disorders are significantly worse. However, details of the clinical course of each hematologic disease remain unclear. Myelodysplastic syndrome (MDS) presents with progressive pancytopenia that has the risk of infection, hemorrhage, and transformation to acute myelogenous leukemia.

View Article and Find Full Text PDF

Fluoroquinolones (FQs) are a widely prescribed class of antibiotics including ciprofloxacin, levofloxacin, and ofloxacin. They are commonly used to treat a variety of infections worldwide. Known for their broad-spectrum antimicrobial activity, as well as excellent pharmacokinetics and bioavailability, the use of FQs has risen significantly.

View Article and Find Full Text PDF

In surgery for acute type A aortic dissection, controlling bleeding from the posterior wall of the proximal anastomosis is particularly challenging. To address this, we use the "reversed turn-up technique." For the reinforcement of the proximal aortic stump, Teflon felt strips were placed inside and outside the suture line with 4-0 polypropylene continuous transverse mattress sutures, and BioGlue was applied to the false lumen.

View Article and Find Full Text PDF

Survival after surgery for acute type A aortic dissection in octogenarians.

J Geriatr Cardiol

November 2024

Department of Cardiovascular Surgery, Centro Cardiologico Monzino IRCCS, Milan, Italy.

Objective: To evaluate the benefits of surgical repair acute type A aortic dissection (ATAAD) on survival of octogenarians.

Methods: Patients who underwent surgery for acute ATAAD from the multicenter European Registry of Type A Aortic Dissection (ERTAAD) were the subjects of the present analysis.

Results: 326 (8.

View Article and Find Full Text PDF