A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Augmented Reality on a C-Arm System: A Preclinical Assessment for Percutaneous Needle Localization. | LitMetric

Augmented Reality on a C-Arm System: A Preclinical Assessment for Percutaneous Needle Localization.

Radiology

From the Department of Radiology, Division of Pediatric Interventional Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH 45229-3030 (John Racadio, R.S., Judy Racadio); and Interventional X-Ray Department, Philips Healthcare, Best, the Netherlands (R.N., R.H., D.B.).

Published: October 2016

Purpose To compare the navigational accuracy and radiation dose during needle localization of targets for augmented reality (AR) with and without motion compensation (MC) versus those for cone-beam computed tomography (CT) with real-time fluoroscopy navigation in a pig model. Materials and Methods This study was approved by the Institutional Animal Care and Use Committee. Three operators each localized 15 targets (bone fragments) approximately 7 cm deep in the paraspinal muscles of nine Yorkshire pigs by using each of the three modalities (AR with and without MC and cone-beam CT with fluoroscopy). Target depth, accuracy (distance between needle tip and target), and radiation dose (dose-area product [DAP]) were recorded for each procedure. Correlation between accuracy and depth of target was assessed by using the Pearson correlation coefficient. Two-way analysis of variance was used for differentiating accuracy and DAPs across navigation techniques and operator backgrounds. Results There was no correlation between depth of target and accuracy. There was no significant difference in accuracy between modalities (mean distance, 3.0 mm ± 1.9 [standard deviation] for cone-beam CT with fluoroscopy, 2.5 mm ± 2.0 for AR, and 3.2 mm ± 2.7 for AR with MC [P = .33]). There was, however, a significant difference in fluoroscopy radiation dose (10.4 Gy · cm(2) ± 10.6 for cone-beam CT fluoroscopy, 2.3 Gy · cm(2) ± 2.4 for AR, and 3.3 Gy · cm(2) ± 4.6 for AR with MC [P < .05]) and therefore in total procedural radiation dose (20.5 Gy · cm(2) ± 13.4 for cone-beam CT fluoroscopy, 12.6 Gy · cm(2) ± 5.3 for AR, 13.6 Gy · cm(2) ± 7.4 for AR with MC [P < .05]). Conclusion Use of an AR C-arm system reduces radiation dose while maintaining navigational accuracy compared with cone-beam CT fluoroscopy during image-guided percutaneous needle placement in a pig model. (©) RSNA, 2016 Online supplemental material is available for this article.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2016151040DOI Listing

Publication Analysis

Top Keywords

radiation dose
20
cone-beam fluoroscopy
20
augmented reality
8
c-arm system
8
percutaneous needle
8
needle localization
8
navigational accuracy
8
pig model
8
depth target
8
cm2 05]
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!