A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly sensitive enzyme-free immunosorbent assay for porcine circovirus type 2 antibody using Au-Pt/SiO2 nanocomposites as labels. | LitMetric

Highly sensitive enzyme-free immunosorbent assay for porcine circovirus type 2 antibody using Au-Pt/SiO2 nanocomposites as labels.

Biosens Bioelectron

State Key Laboratory of Agricultural Microbiology, College of Food Science and Technology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China. Electronic address:

Published: August 2016

Improving the performance of conventional enzyme-linked immunosorbent assay (ELISA) is of great importance to meet the demand of early clinical diagnosis of various diseases. Herein, we report a feasible enzyme-free immunosorbent assay (EFISA) system using antibody conjugated Au-Pt/SiO2 nanocomposites (APS NCs) as labels. In this system, Au-Pt/SiO2 nanospheres (APS NPs) were first synthesized by wet chemical method and exhibited intrinsic peroxidase and catalase-like activity with excellent water-solubility. Then APS NCs were utilized as labels to replace HRP conjugated antibody, and Fe3O4 magnetic beads (MBs) to entrap the analyte. To discuss the performance of EFISA system, Human IgG was served as a model analyte, and porcine circovirus type 2 (PCV2) serums as real samples. The system boosted the detection limit of HIgG to 75pgmL(-1) with a RSD below 5%, a 264-fold improvement as compared with conventional ELISA. This is the first time that APS NCs have been used and successfully optimized for the sensitive dilution detection of PCV2 antibody (5:10(7)) in ELISA. Besides, APS NCs have advantages related to low cost, easy preparation, good stability and tunable catalytic activity, which make them a potent enzyme mimetic candidate and may find potential applications in bioassays and clinical diagnostics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2016.04.001DOI Listing

Publication Analysis

Top Keywords

aps ncs
16
immunosorbent assay
12
enzyme-free immunosorbent
8
porcine circovirus
8
circovirus type
8
au-pt/sio2 nanocomposites
8
efisa system
8
aps
5
highly sensitive
4
sensitive enzyme-free
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!