Purpose: We aimed to derive a "robustness recipe" giving the range robustness (RR) and setup robustness (SR) settings (ie, the error values) that ensure adequate clinical target volume (CTV) coverage in oropharyngeal cancer patients for given gaussian distributions of systematic setup, random setup, and range errors (characterized by standard deviations of Σ, σ, and ρ, respectively) when used in minimax worst-case robust intensity modulated proton therapy (IMPT) optimization.

Methods And Materials: For the analysis, contoured computed tomography (CT) scans of 9 unilateral and 9 bilateral patients were used. An IMPT plan was considered robust if, for at least 98% of the simulated fractionated treatments, 98% of the CTV received 95% or more of the prescribed dose. For fast assessment of the CTV coverage for given error distributions (ie, different values of Σ, σ, and ρ), polynomial chaos methods were used. Separate recipes were derived for the unilateral and bilateral cases using one patient from each group, and all 18 patients were included in the validation of the recipes.

Results: Treatment plans for bilateral cases are intrinsically more robust than those for unilateral cases. The required RR only depends on the ρ, and SR can be fitted by second-order polynomials in Σ and σ. The formulas for the derived robustness recipes are as follows: Unilateral patients need SR = -0.15Σ(2) + 0.27σ(2) + 1.85Σ - 0.06σ + 1.22 and RR=3% for ρ = 1% and ρ = 2%; bilateral patients need SR = -0.07Σ(2) + 0.19σ(2) + 1.34Σ - 0.07σ + 1.17 and RR=3% and 4% for ρ = 1% and 2%, respectively. For the recipe validation, 2 plans were generated for each of the 18 patients corresponding to Σ = σ = 1.5 mm and ρ = 0% and 2%. Thirty-four plans had adequate CTV coverage in 98% or more of the simulated fractionated treatments; the remaining 2 had adequate coverage in 97.8% and 97.9%.

Conclusions: Robustness recipes were derived that can be used in minimax robust optimization of IMPT treatment plans to ensure adequate CTV coverage for oropharyngeal cancer patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2016.02.035DOI Listing

Publication Analysis

Top Keywords

ctv coverage
16
robustness recipes
12
oropharyngeal cancer
12
cancer patients
12
minimax robust
8
robust optimization
8
intensity modulated
8
modulated proton
8
proton therapy
8
patients
8

Similar Publications

Contour uncertainty assessment for MD-omitted daily adaptive online head and neck radiotherapy.

Radiother Oncol

January 2025

Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA; Medical Artificial Intelligence and Automation Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA. Electronic address:

Background And Purpose: Daily online adaptive radiotherapy (DART) increases treatment accuracy by crafting daily customized plans that adjust to the patient's daily setup and anatomy. The routine application of DART is limited by its resource-intensive processes. This study proposes a novel DART strategy for head and neck squamous cell carcinoma (HNSCC), automizing the process by propagating physician-edited treatment contours for each fraction.

View Article and Find Full Text PDF

We assessed the effect of beam size on plan robustness for intensity-modulated proton therapy (IMPT) of head and neck cancer (HNC) and compared the plan quality including robustness with that of intensity-modulated radiation therapy (IMRT). IMPT plans were generated for six HNC patients using six beam sizes (air-sigma 3-17 mm at isocenter for a 70-230 MeV) and two optimization methods for planning target volume-based non-robust optimization (NRO) and clinical target volume (CTV)-based robust optimization (RO). Worst-case dosimetric parameters and plan robustness for CTV and organs-at-risk (OARs) were assessed under different scenarios, assuming a ± 1-5 mm setup error and a ± 3% range error.

View Article and Find Full Text PDF

Introduction: Following a preliminary work validating the technological feasibility of an adaptive workflow with Ethos for whole-breast cancer, this study aims to clinically evaluate the automatic segmentation generated by Ethos.

Material And Methods: Twenty patients initially treated on a TrueBeam accelerator for different breast cancer indications (right/left, lumpectomy/mastectomy) were replanned using the Ethos emulator. The adaptive workflow was performed using 5 randomly selected extended CBCTs per patient.

View Article and Find Full Text PDF

Background And Purpose: Conventionally, the quality of radiotherapy treatment plans is assessed through visual inspection of dose distributions and dose-volume histograms. This study developed a framework to evaluate plan quality using dose, complexity, and robustness metrics. Additionally, a method for predicting plan robustness metrics using dose and complexity metrics was introduced for cases where plan robustness evaluation is unavailable or impractical.

View Article and Find Full Text PDF

Purpose: To compare intensity-modulated proton therapy with CyberKnife (CK) therapy for hypo-fractionated treatments of prostate with focal boost, as a first planning study for prostate with dose escalation to a dominant intraprostatic lesion (DIL).

Materials And Methods: Ten patients who possess one DIL in their prostate and their CK plans that were used to treat the planning target volume of prostate were chosen. Six of the plans were further escalated to DIL.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!