Objective measurements of transverse chromatic aberration (TCA) between two or more wavelengths with an adaptive optics scanning laser ophthalmoscope (AOSLO) are very accurate, but frequent measurements are impractical in many experimental settings. Here, we demonstrate a pupil tracker that can accurately measure relative changes in TCA that are caused by small shifts in the pupil relative to the AOSLO imaging beam. Corrections for TCA caused by these shifts improve the measurement of TCA as a function of eccentricity, revealing a strong linear relationship. We propose that pupil tracking be integrated into AOSLO systems, where robust and unobtrusive control of TCA is required.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322945 | PMC |
http://dx.doi.org/10.1364/OL.41.001728 | DOI Listing |
Biomed Opt Express
May 2024
Department of Psychology, University of Pennsylvania, Goddard Laboratories, Philadelphia, PA 19104, USA.
It has been known for more than 220 years that the image quality of the human eye is significantly degraded by chromatic aberrations. Recently, it was shown experimentally that correcting chromatic aberrations results in a 0.2- to 0.
View Article and Find Full Text PDFMetalenses are considered a promising solution for miniaturizing numerous optical systems due to their light weight, ultrathin thickness and compact size. However, it remains a challenge for metalenses to achieve both wide field-of-view and broadband achromatic imaging. In this work, a single-layer achromatic metalens with a wide field-of-view of 160° in the 3800 nm-4200 nm band is designed and analyzed.
View Article and Find Full Text PDFBiomed Opt Express
July 2023
Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.
Digital correction of optical aberrations allows for high-resolution imaging across the full depth range in optical coherence tomography (OCT). Many digital aberration correction (DAC) methods have been proposed in the past to evaluate and correct monochromatic error in OCT images. However, other factors that deteriorate the image quality have not been fully investigated.
View Article and Find Full Text PDFJ Vis
February 2023
Herbert Wertheim School of Optometry and Vision Science, University of California at Berkeley, Berkeley, CA, USA.
Metalenses are attracting a large interest for the implementation of complex optical functionalities in planar and compact devices. However, chromatic and off-axis aberrations remain standing challenges. Here, we experimentally investigate the broadband behavior of metalenses based on quadratic phase profiles.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!