Soft-tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface-based metrics, and subsurface validation has largely been performed via phantom experiments. The proposed method involves the analysis of two deformation-correction algorithms for open hepatic image-guided surgery systems via subsurface targets digitized with tracked intraoperative ultrasound (iUS). Intraoperative surface digitizations were acquired via a laser range scanner and an optically tracked stylus for the purposes of computing the physical-to-image space registration and for use in retrospective deformation-correction algorithms. Upon completion of surface digitization, the organ was interrogated with a tracked iUS transducer where the iUS images and corresponding tracked locations were recorded. Mean closest-point distances between the feature contours delineated in the iUS images and corresponding three-dimensional anatomical model generated from preoperative tomograms were computed to quantify the extent to which the deformation-correction algorithms improved registration accuracy. The results for six patients, including eight anatomical targets, indicate that deformation correction can facilitate reduction in target error of [Formula: see text].
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4804127 | PMC |
http://dx.doi.org/10.1117/1.JMI.3.1.015003 | DOI Listing |
Technol Cancer Res Treat
February 2024
Department of Radiotherapy, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou, China.
Sensors (Basel)
May 2023
Department of Industrial Engineering and Management, Chaoyang University of Technology, Taichung 413310, Taiwan.
Multifocal glasses are a new type of lens that can fit both nearsighted and farsighted vision on the same lens. This property allows the glass to have various curvatures in distinct regions within the glass during the grinding process. However, when the curvature varies irregularly, the glass is prone to optical deformation during imaging.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
TRUS-MR fusion guided biopsy highly depends on the quality of alignment between pre-operative Magnetic Resonance (MR) image and live trans-rectal ultrasound (TRUS) image during biopsy. Lot of factors influence the alignment of prostate during the biopsy like rigid motion due to patient movement and deformation of the prostate due to probe pressure. For MR-TRUS alignment during live procedure, the efficiency of the algorithm and accuracy plays an important role.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
November 2020
Medical Institute of Developmental Disabilities Research, Showa University.
Int J Comput Assist Radiol Surg
May 2018
Technical University of Munich, Boltzmannstr. 3, 85748, Garching bei München, Germany.
Purpose: Ultrasound acquisitions are typically affected by deformations due to the pressure applied onto the contact surface. While a certain amount of pressure is necessary to ensure good acoustic coupling and visibility of the anatomy under examination, the caused deformations hinder accurate localization and geometric analysis of anatomical structures. These complications have even greater impact in case of 3D ultrasound scans as they limit the correct reconstruction of acquired volumes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!