  • The study evaluated the effectiveness of the Thyroid Imaging Reporting and Data System (TIRADS) in predicting malignancy in thyroid nodules and how consistently different radiologists used this system.
  • A total of 238 patients with thyroid nodules were analyzed, and the positive predictive value (PPV) for cancer increased significantly across different TIRADS categories, with category 5 having a PPV of 91%.
  • The inter-observer agreement among radiologists when assessing ultrasound features was found to be substantial, making TIRADS a reliable and practical tool for thyroid nodule evaluation.

Article Abstract

Aim: To assess the positive predictive value (PPV) and inter-observer agreement of Thyroid Imaging Reporting and Data System (TIRADS) as described by Kwak et al.

Materials And Methods: This was a prospective study wherein ultrasound was performed by two radiologists on patients with thyroid nodules >1 cm. The third radiologist interpreted archived images. Ultrasound features and TIRADS category were compared with cytology and surgical histopathology. PPV was calculated for all readers' combined assessment. Inter-observer agreement was calculated using linear weighted kappa.

Results: A total of 238 patients with 272 nodules of mean size 2.9 ± 1.7 cm were included. PPV for malignancy was 6.6%, 32%, 36%, 64%, 59%, and 91% for TIRADS 2, 3, 4a, 4b, 4c, and 5 categories, respectively. Inter-observer agreement was substantial [kappa (k) = 0.61-0.80] for assessment of nodule echogenicity, margins, calcification, and shape and good (k = 0.570, P < 0.001) for assessment of composition of the thyroid nodules. Overall agreement between observers was substantial for assigning TIRADS category [multi-rater weighted kappa coefficient (wt k) = 0.721, P < 0.001].

Conclusions: TIRADS is a simple and practical method of assessing thyroid nodules with high PPV and good inter-observer agreement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813066PMC
http://dx.doi.org/10.4103/0971-3026.178367DOI Listing

Publication Analysis

Top Keywords

inter-observer agreement
16
thyroid nodules
12
tirads category
8
tirads
6
agreement
5
tirads practical
4
practical accurate
4
accurate system
4
system daily
4
daily clinical
4

Similar Publications

SEPO-FI: Deep-learning based software to calculate fusion index of muscle cells.

Comput Biol Med

January 2025

School of Computer Science, Chungbuk National University, Cheongju 28644, Republic of Korea. Electronic address:

The fusion index is a critical metric for quantitatively assessing the transformation of in vitro muscle cells into myotubes in the biological and medical fields. Traditional methods for calculating this index manually involve the labor-intensive counting of numerous muscle cell nuclei in images, which necessitates determining whether each nucleus is located inside or outside the myotubes, leading to significant inter-observer variation. To address these challenges, this study proposes a three-stage process that integrates the strengths of pattern recognition and deep-learning to automatically calculate the fusion index.

View Article and Find Full Text PDF

: The aim of this study is to assess the inter- and intra-observer reproducibility of the identification of direct and indirect ultrasonographic features of adenomyosis as defined by the revised Morphological Uterus Sonographic Assessment (MUSA) consensus (2022). : A cohort of 74 women, aged 18 to 45, were recruited from the recurrent miscarriage and general gynaecology clinic at a university-based fertility centre. All the participants underwent 2D and 3D transvaginal Ultrasound scan (TVS) examination in the late follicular and early luteal phase.

View Article and Find Full Text PDF

Objectives: To assess the diagnostic accuracy, in a validation cohort, of a score based on three CT items, which has shown good performance for predicting ischaemia complicating acute adhesive small-bowel obstruction (SBO).

Methods: This retrospective single-centre study of diagnostic accuracy included consecutive patients admitted for acute adhesive SBO in 2015-2022, who were treated conservatively or underwent surgery within 24 h after CT. The gold standard for ischaemia was an intraoperative diagnosis for operated patients, while the absence of ischaemia was confirmed either by its absence during surgery or by clinical follow-up in patients who did not undergo surgery.

View Article and Find Full Text PDF

We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included.

View Article and Find Full Text PDF

Purpose: The study aimed to assess the reliability of tele-education in training a Malawian ophthalmology resident to interpret optical coherence tomography (OCT) images of patients with macular conditions.

Methods: This was a retrospective analysis of 1000 macula-centered OCT image series from 1000 eyes of 1000 consecutive patients from Malawi, which involved initial interpretation by a German retina specialist (observer 1) (T). Observer 1 then trained a Malawian resident (observer 2) via email, and observer 2 independently interpreted images at T, followed by face-to-face training in Malawi and reinterpretation at T and T (3-month intervals).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!