The Glidescope® is one of the most widely used video laryngoscopes in the market. It is often used with a purpose-built, reusable, "nonmalleable" stainless steel stylet, the GlideRite®. In this study, we investigated whether this stylet retains its original curvature with repeated use and sterilization. To evaluate the shape and curvature of the stylets, high-resolution digital photographs were made of 55 GlideRite stylets (5 new and 50 randomly selected from operating room stock) laid on a grid background and analyzed using Adobe Photoshop®. In a similar fashion, 1 new stylet was inserted into and removed 100 times from an endotracheal tube and photographed every 20 cycles to determine the impact of use on stylet shape. For the 5 new stylets, the handle-to-tip angle was very consistent (23.44° ± 1.04°). The stylets in clinical use varied widely in their configuration. For analysis, they were divided into 3 groups based on the handle-to-tip angle: ±1 SD of the new stylets, those with a shallower angle (straighter), and those with a steeper angle (more curved). The handle-to-tip angles were as follows: 23.07° ± 0.80° (±1 SD), 18.39° ± 2.59° (straighter), and 27.65° ± 2.73° (more curved). Analysis of variance showed that the new and ±1 SD groups were not significantly different, but both the straighter (P = 0.0002) and more curved (P = 0.0048) groups were significantly different from new. The repeated insertion and removal of a new stylet resulted in gradual straightening of the curve of the stylet from 22° at baseline to 19.2° after 100 insertion/removal cycles. Used GlideRite reusable stylets are not reliably equivalent to new ones in terms of their shape or curvature. Given that the repeated insertion and removal of a new stylet from an endotracheal tube resulted in their straightening, it is likely that clinical use has the same effect. Because many used stylets were actually more curved than the new ones, we hypothesize that practitioners likely bend the nonmalleable stylets to improve clinical utility, but often fail to recapture the manufacturer-intended curve. The clinical relevance of the change in shape of the GlideRite stylet remains to be determined; it is that possible intubation may be more difficult than expected compared with the use of new stylets.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1213/XAA.0000000000000303 | DOI Listing |
Pest Manag Sci
January 2025
College of Plant Science and Technology, Huazhong Agricultural University, Wuhan, China.
Background: The cotton-melon aphid, Aphis gossypii Glover, is a polyphagous pest damaging plants across over 100 families. It has multiple host-specialized lineages, including one colonizing Malvaceae (MA) and one colonizing Cucurbitaceae (CU). The mechanisms underlying these host relationships remain unknown.
View Article and Find Full Text PDFBMC Anesthesiol
January 2025
Department of Anesthesia, ICU & Pain, Faculty of Medicine (Boys), Al-Azhar University, Cairo, Egypt.
Background: Endotracheal intubation (ETI) is a life-saving procedure that must be accurately carried on to guard against complications. Presbyopia leads to difficulty in viewing close objects and may obstacle proper intubation even with the best hands.
Purpose: This study supposed that the use of video-laryngoscope (VL) may provide better intubation conditions for presbyopic anesthetists and targets to evaluate the neonates and infants' intubation success rates (ISR) by anesthetists aged ≥ 45 years using the C-MAC VL compared to the standard laryngoscope (SL).
Surg Neurol Int
December 2024
Department of Neurosurgery, University of California, Irvine, Orange, United States.
Background: Stereoelectroencephalography (SEEG) is a common diagnostic surgical procedure for patients with medically refractory epilepsy. We aimed to describe our initial experience with the recently released NeuroOne Evo SEEG electrode product (Zimmer Biomet, Warsaw, IN) and review technical specifications for other currently approved depth SEEG electrodes.
Methods: We performed a record review on the first five patients implanted with NeuroOne Evo SEEG electrode product using the robotic stereotactic assistance robot platform and described our surgical technique in detail.
Crit Care Med
January 2025
Department of Medicine, University of Wisconsin School of Medicine & Public Health, Madison, WI.
Objectives: Diabetes mellitus has been associated with greater difficulty of tracheal intubation in the operating room. This relationship has not been examined for tracheal intubation of critically ill adults. We examined whether diabetes mellitus was independently associated with the time from induction of anesthesia to intubation of the trachea among critically ill adults.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Anaesthesia and Intensive Care, Policlinico-San Marco University Hospital, Via S. Sofia n 78, 95123 Catania, Italy.
Simulation offers the opportunity to train healthcare professionals in complex scenarios, such as those with as traumatized patients. We conducted an observational cross-sectional research simulating trauma with cervical immobilization. We compared five techniques/devices: direct laryngoscopy (DL), videolaryngoscopy (VLS, Glidescope or McGrath), combined laryngo-bronchoscopy intubation (CLBI) and articulating video stylet (ProVu).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!