A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A reusable microfluidic device provides continuous measurement capability and improves the detection limit of digital biology. | LitMetric

Current digital biology platforms lack the ability to perform continuous measurements for transient analysis. A fundamental challenge is to perform complex fluidic manipulation processes such as washing and mixing in individual reaction volumes. Here, we present a reusable digital biology platform where the reaction compartmentalization and commencement are controlled by micromechanical valves fabricated in high density through microfluidic very large scale integration (mVLSI) technology. Background noise correction enabled by the platform improves signal-to-noise ratio and thus eliminates the need for sophisticated imaging technologies. We have used the detection platform for probing single molecules of the β-galactosidase enzyme. The measurements were repeated hundreds of times at concentrations as low as 0.8 fM (resulting in a theoretical detection limit of 3 aM). We have also demonstrated multiple TNF-α measurements with a magnetic bead based digital ELISA assay. The assay showed that the average number of enzymes per magnetic bead is 0.55 for 10 pM TNF-α (compared to 0.08 for negative control). This automated and reusable digital platform allows on-chip assay preparation and continuous measurements; as a result, it will enable single cell/enzyme studies and clinical diagnostic tests (i.e. digital ELISA) to be performed in shorter time scales and with lower detection limits.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c6lc00194gDOI Listing

Publication Analysis

Top Keywords

digital biology
12
detection limit
8
continuous measurements
8
reusable digital
8
magnetic bead
8
digital elisa
8
digital
6
reusable microfluidic
4
microfluidic device
4
device continuous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!