Design of push-pull system to control diesel particular matter inside a dead-end entry.

Int J Coal Sci Technol

Division of Mining and Resources Engineering, Department of Civil Engineering, Monash University, Clayton Campus, Wellington Road, Clayton, VIC 3800 Australia.

Published: August 2015

Diesel particulate matter (DPM) is considered to be carcinogenic after prolonged exposure. With more diesel-powered equipment used in underground mines, miners' exposure to DPM has become an increasing concern. This paper used computational fluid dynamics method to study the DPM dispersion in a dead-end entry with loading operation. The effects of different push-pull ventilation systems on DPM distribution were evaluated to improve the working conditions for underground miners. The four push-pull systems considered include: long push and short pull tubing; short push and long pull tubing, long push and curved pull tubing, and short push and curved pull tubing. A species transport model with buoyancy effect was used to examine the DPM dispersion pattern with unsteady state analysis. During the 200 s of loading operation, high DPM levels were identified in the face and dead-end entry regions. This study can be used for mining engineer as guidance to design and setup local ventilation, select DPM control strategies and for DPM annual training for underground miners.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4811165PMC
http://dx.doi.org/10.1007/s40789-015-0076-zDOI Listing

Publication Analysis

Top Keywords

pull tubing
16
dead-end entry
12
dpm
8
dpm dispersion
8
loading operation
8
underground miners
8
long push
8
tubing short
8
short push
8
push curved
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!