A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel Sirolimus-Coated Balloon Catheter: In Vivo Evaluation in a Porcine Coronary Model. | LitMetric

Novel Sirolimus-Coated Balloon Catheter: In Vivo Evaluation in a Porcine Coronary Model.

Circ Cardiovasc Interv

From the Klinik für Innere Medizin III, Kardiologie, Angiologie und internistische Intensivmedizin, Universitätsklinikum des Saarlandes, Homburg/Saar, Germany (Y.P.C., S.B., B.C., M.B., B.S.); Institut für Radiologie, Charité-Universitätsmedizin Berlin, Campus Mitte, Humboldt Universität zu Berlin, Germany (D.P., B.K., U.S.); and B. Braun Melsungen AG, Berlin, Germany (J.C., M.-C.B., C.S., M.S.).

Published: April 2016

Background: Limus-eluting stents are dominating coronary interventions, although paclitaxel is the only drug on balloon catheters with proven inhibition of restenosis. Neointimal inhibition by limus-coated balloons has been shown in few animal studies, but data from randomized clinical trials are not available. The aim of the present preclinical studies was to achieve high and persistent sirolimus levels in the vessel wall after administration by a coated balloon.

Methods And Results: Different coating formulations and doses were studied in the porcine coronary model to investigate sirolimus tissue levels at different time points as well as efficacy at 1 month using quantitative coronary angiography and histomorphometry. Loss of the selected coating in the valve, guiding catheter, and blood was low (2±14% of dose). Acute drug transfer to the vessel wall was 14.4±4.6% with the crystalline coating, whereas the amorphous coatings were less effective in this respect. Persistence of sirolimus in the vessel wall until 1 month was 40% to 50% of the transferred drug. At 1-month follow-up, a modest but significant reduction of neointimal growth was demonstrated in a dose range from 4 μg/mm(2) to 2×7 μg/mm(2), for example, maximum neointimal thickness of 0.38±0.13 versus 0.65±0.21 mm in the uncoated control group.

Conclusions: Various sirolimus-coated balloons effectively reduce neointimal proliferation in the porcine coronary model but differ considerably in retention time in the vessel wall. It has to be determined if such a formulation with persistent high vessel concentration will result in a relevant clinical effect.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.115.003543DOI Listing

Publication Analysis

Top Keywords

vessel wall
16
porcine coronary
12
coronary model
12
coronary
5
vessel
5
novel sirolimus-coated
4
sirolimus-coated balloon
4
balloon catheter
4
catheter vivo
4
vivo evaluation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!