AI Article Synopsis

Article Abstract

Background: This study investigated diffusion-weighted (DWI) magnetic resonance imaging (MRI) as an alternative to fat-suppressed T2-weighted imaging (FS-T2WI) for assessment of partial-thickness rotator cuff tears (RCTs).

Methods: Patients with arthroscopy proven partial-thickness RCTs who also received MRI (FS-T2WI and DWI) before surgery were prospectively included. Receiver operating characteristic curves were used to compare DWI vs. FS-T2WI using lesion-to-muscle signal intensity ratios. A cutoff point for predicting partial-thickness tears was determined using the Youden index.

Results: Included were 146 patients, with a mean age of 48.3 years (range, 19-86 years), of whom 43 had full-thickness RCTs, 67 had partial-thickness RCTs, and 36 had no tears. Areas under receiver operating characteristic curves for diagnosing partial-thickness tears were significantly higher for DWI (0.910) than for FS-T2WI (0.822, P = .016). Lesion-to-muscle signal intensity ratio cutoff values were 1.06 for DWI vs. 1.65 for FS-T2WI, respectively. The sensitivity and accuracy of DWI (89.1% [98 of 110] and 87.7% [128 of 146], respectively) for diagnosing partial-thickness and full-thickness tears were higher than for FS-T2WI (65.5% [72 of 110] and 72.6% [106 of 146], respectively). FS-T2WI, however, had higher specificity (94.4% [34 of 36]) than DWI (83.3% [30 of 36]).

Conclusions: DWI is more accurate and sensitive than FS-T2WI for diagnosing partial-thickness RCTs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2016.01.020DOI Listing

Publication Analysis

Top Keywords

partial-thickness rcts
12
diagnosing partial-thickness
12
magnetic resonance
8
resonance imaging
8
partial-thickness
8
partial-thickness rotator
8
rotator cuff
8
cuff tears
8
dwi
8
fs-t2wi
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!