Background: Shoulder outcome scores that include range of motion (ROM) and apprehension signs are limited by the need for direct involvement of the physician. Patient-reported outcome measures are patient centered and self-administered, and they can help physicians track the patient's progress between office visits and for long-term follow-up once the patient has been discharged.
Methods: Thirty consecutive patients completed a form before their 6-month follow-up after surgery on the labrum or capsule as a result of instability or pain related to instability. The form included bilateral ROM, apprehension, and instability episodes. The same parameters were measured by the physician during the visit. The patient's and physician's responses were compared. The primary outcome was the percentage agreement with exact and approximate agreement.
Results: Exact agreement was moderate for forward elevation at 56.6%; fair for abduction and external rotation at 90° at 24.5% and 34%, respectively; and poor for internal rotation at 90° and external rotation with the arm at the side at 2.6% and 12%, respectively. Approximate agreement within a range of positive or negative 20° range was very good for forward elevation (94%), abduction (92%), and external rotation at 90° (87%); moderate for external rotation with the arm at the side; and fair for internal rotation at 90°. There was 70% agreement regarding apprehension, 93% regarding subluxation events, and 100% regarding redislocation events.
Conclusion: Some measures of shoulder ROM showed a moderate to high level of agreement between patient-reported measurements and the physician's measurements. This method for short- and long-term follow-up could potentially replace routine clinic visits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2016.02.010 | DOI Listing |
Am J Ind Med
January 2025
National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA.
Background: This study aimed to assess how knee savers (KSs) and knee pads (KPs) alleviate risks of knee musculoskeletal disorders (MSDs) among roofers during various phases of shingle installation. These phases encompass (1) reaching for shingles, (2) placing shingles, (3) grabbing a nail gun, (4) moving to the first nailing position, (5) nailing shingles, (6) replacing the nail gun, and (7) returning to an upright position.
Methods: In a laboratory setting, nine male participants simulated the shingle installation task on a slope-adjustable roof platform (0°, 15°, and 30° slopes) under four intervention conditions: no intervention (NO); with KPs only (KP); with KSs only (KS); and with both KPs and KSs (BO).
Biomed Eng Lett
January 2025
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505 South Korea.
Unlabelled: Accurate assessment of shoulder range of motion (ROM) is crucial for evaluating patient progress. Traditional manual goniometry often lacks precision and is subject to inter-observer variability, especially in measuring shoulder internal rotation (IR). This study introduces an artificial intelligence (AI)-based approach that uses clinical photography to improve the accuracy of ROM quantification.
View Article and Find Full Text PDFJ Neuroeng Rehabil
January 2025
Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
Background: Motion complexity is necessary for adapting to external changes, but little is known about trunk motion complexity during seated perturbation in individuals with spinal cord injury (SCI). We aimed to investigate changes following SCI in trunk segmental motion complexity across different perturbation directions and how they affect postural control ability in individuals with SCI.
Methods: A total of 17 individuals with SCI and 18 healthy controls participated in challenging sagittal-seated perturbations with hand protection.
Curr Rev Musculoskelet Med
January 2025
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
Purpose Of Review: With the growing popularity and broadening indications for Reverse Shoulder Arthroplasty (RSA), increasing modularity in design and adjustments to each component can enhance postoperative range of motion (ROM), thus expanding treatment capabilities. This review outlines the advancements developed to optimize ROM through modifications in glenoid and humeral components and the integration of computational tools for surgical planning.
Recent Findings: Enhancements in glenoid component design aim to mitigate complications like scapular notching and improve ROM, particularly in abduction and external rotation.
Clin Orthop Relat Res
January 2025
Department of Orthopaedic Surgery, Mayo Clinic, Jacksonville, FL, USA.
Background: A variety of clinically important benchmarks of success (CIBS) have been defined for total shoulder arthroplasty (TSA) to quantify success. However, it is unclear how the preoperative status of the patient influences their likelihood of achieving each CIBS.
Questions/purposes: (1) What proportion of patients achieve commonly used CIBS after TSA? (2) Is there a relationship between a patients' preoperative function and their probability of achieving different CIBS? (3) Does there exist preoperative ranges for each outcome measure that are associated with greater achievement of CIBS?
Methods: We retrospectively queried a multicenter shoulder arthroplasty database for primary anatomic TSA (aTSA) and reverse TSA (rTSA).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!