Experiments were done to determine whether the starting position of the arm influences its final configuration (posture) when pointing to, or grasping, targets located within the common workspace of the arm. Subjects were asked to point to, or grasp, each of six targets from five, or seven, widely spaced starting positions. We found that the variability (standard deviation) of the arm's configuration, measured as the angle of inclination of the plane delimited by the arm and forearm, averaged about 4° for comfortable speed pointing movements and was only slightly higher for fast pointing movements. Comfortable speed reaches to grasp the targets were associated with slightly lower variability (3.5°) in final arm configuration. The average variability of repeated movements to a given target from a single start position (3.5°) was comparable to that of movements from different start positions to the same target (4.2°). A small difference in final arm inclination angle, averaged across all subjects and targets, of 3° was found between two pairs of starting positions. This small and possibly idiosyncratic effect is within the "noise" of final arm orientation variability for repeated movements (i.e., 3.5°). Thus, the variability of final posture is not for the most part due to different start positions, it is inherent to movement per se. Our results reconcile conflicting previous studies and are consistent with past works suggesting that a Donders' like law is indeed largely upheld for unconstrained visually guided arm movements. In summary, considering movements within a typical work space, when the hand is moved voluntarily to a given spatial location the posture of the arm is nearly the same regardless of its starting position. Importantly, variability is inherent to the rule.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4811900 | PMC |
http://dx.doi.org/10.3389/fnhum.2016.00136 | DOI Listing |
Stem Cell Res Ther
January 2025
Department of Medicine, Veterans Affairs Medical Center, Washington, DC, USA.
Introduction: Effects of Dapagliflozin (Dapa) and Dapagliflozin-Saxagliptin combination (Combo) was examined on peripheral blood derived CD34 + Hematopoetic Stem Cells (HSCs) as a cellular CVD biomarker. Both Dapa (a sodium-glucose co-transporter 2 or SGLT2, receptor inhibitor) and Saxagliptin (a Di-peptydl-peptidase-4 or DPP4 enzyme inhibitor) are commonly used type 2 diabetes mellitus or T2DM medications, however the benefit of using the combination has not been evaluated for cardio-renal risk assessment, in a real-life practice setting, compared to a placebo.
Hypothesis: We hypothesized that Dapa will improve the outcomes when compared to placebo and the Combo maybe even more beneficial.
J Shoulder Elbow Surg
January 2025
Roth | McFarlane Hand & Upper Limb Center, St Joseph's Health Care London, London, ON, Canada.
Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.
View Article and Find Full Text PDFSensors (Basel)
January 2025
German Center for Vertigo and Balance Disorders (DSGZ), LMU University Hospital, LMU Munich, 81377 Munich, Germany.
Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Orthopedics, Traumatology and Hand Surgery, Faculty of Medicine, Wroclaw Medical University, 50-556 Wroclaw, Poland.
: Lateral elbow tendinopathy is a common condition that significantly alters the function of the upper extremities. In case of first-line treatment failure, different local injections are usually used. Due to the lack of sufficient evidence to support it, we conducted the study to compare the outcomes of different single injections, including Platelet-Rich Plasma (PRP), Corticosteroids (CS), Hyaluronic Acid (HA), and placebo (saline).
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Peachtree Orthopaedic Clinic, Atlanta, GA, USA.
Background: The treatment of patients who suffer a proximal humeral fracture (PHF) remains controversial. The purpose of this study was to find consensus among experts using a validated iterative process in the treatment of patients after a PHF.
Methods: The Neer Circle is an organization of shoulder experts recognized for their service to the American Shoulder and Elbow Surgeons.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!