Background: Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable.

Methods: 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30 mL/min) who underwent a novel VLCV protocol (20 mL of iohexol at 2.5 mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale.

Results: VLCV patients had mean (±SD) age 86 ± 6.5, BMI 23.9 ± 3.4 kg/m(2) with 54% men; SCV patients age 83 ± 8.8, BMI 28.7 ± 5.3 kg/m(2), 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement.

Conclusions: This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4958553PMC
http://dx.doi.org/10.1016/j.jcct.2016.03.005DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
valve replacement
12
contrast volume
8
computed tomography
8
tomography angiography
8
providing comprehensive
8
comprehensive cardiac
8
cardiac vascular
8
transcatheter aortic
8
chronic kidney
8

Similar Publications

Novel Real-Time Fluoroscopic Assessment Method of Transcatheter Heart Valve Expansion Following Balloon-Expandable TAVR.

Circ Cardiovasc Interv

January 2025

Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, Canada. (A.H., J.J., S.O., K.M., J.A.L., P.B., D.A.W., S.L.S., J.G.W., J.S.).

Background: Transcatheter heart valve (THV) underexpansion after transcatheter aortic valve replacement may be associated with worse outcomes. THV expansion can be assessed fluoroscopically using a pigtail for calibration; however, the accuracy of this technique specific to transcatheter aortic valve replacement is unknown. We assessed the accuracy and reproducibility of a novel fluoroscopic method to assess THV expansion using the THV commissural post for calibration.

View Article and Find Full Text PDF

Background: Aortic stenosis (AS) is treated through transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR), with diabetes being prevalent among these patients. Inflammation participates in the pathogenesis of AS, and emerging evidence suggests that TAVI may exert anti-inflammatory effects. Given the established link between diabetes and inflammation, we sought to evaluate the impact of aortic valve replacement (AVR) on glycemic control.

View Article and Find Full Text PDF

Multivalvular endocarditis (MVE) is an uncommon presentation and mostly involves mitral and aortic valves. Here, we present a case of an MVE with an unusual and bizarre presentation on a Halloween night with a massive degree of valve destruction and right- and left-side involvement requiring emergent surgery. A 51-year-old male patient with intravenous drug usage presented with anorexia, fever, and dyspnea, rapidly progressing to septic shock with multiorgan dysfunction.

View Article and Find Full Text PDF

Minimally invasive mitral valve replacement redo surgery under ventricular fibrillation in a patient with dextrocardia and situs inversus totalis: a case report.

J Cardiothorac Surg

January 2025

Department of Cardiovascular Surgery, The First Affiliated Hospital, School of Medicine, Zhejiang University, 79#, Qingchun Road, Hangzhou, 310003, China.

Background: Dextrocardia is a rare cardiac malposition where the heart's normal orientation is reversed and is most commonly associated with situs inversus totalis (SIT). Such cases are technically challenging when heart surgery is needed, especially re-do surgery.

Case Presentation: A 72-year-old female patient was referred to our hospital with complaints of chest tightness and reduced activity tolerance.

View Article and Find Full Text PDF

Mitral and aortic annular calcification is an age-related degenerative process that can result in severe mitral and/or aortic stenosis and/or regurgitation. Annular calcification not only increases the surgical complexity but also increases the risk of complications. In this case report, we present the innovative use of the Sonopet ultrasonic surgical aspirator for aortic and mitral annular decalcification in a patient with hypertrophic obstructive cardiomyopathy, mild aortic stenosis and moderate mitral regurgitation in the presence of mitral annular calcification (MAC) and aorto-mitral curtain calcification.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!