A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous analysis of gemfibrozil, morphine, and its two active metabolites in different mouse brain structures using solid-phase extraction with ultra-high performance liquid chromatography and tandem mass spectrometry with a deuterated internal standard. | LitMetric

A rapid and sensitive bioassay was established and validated to simultaneously determine gemfibrozil, morphine, morphine-3β-glucuronide, and morphine-6β-glucuronide in mouse cerebrum, epencephalon, and hippocampus based on ultra-high performance liquid chromatography and tandem mass spectrometry. The deuterated internal standard, M6G-d3, was mixed with the prepared samples at 10 ng/mL as the final concentration. The samples were transferred into the C18 solid-phase extraction columns with gradient elution for solid-phase extraction. The mobile phase consisted of methanol and 0.05% formic acid (pH 3.2). Multiple reaction monitoring has been applied to analyze gemfibrozil (m/z 249.0 → 121.0) in anion mode, and M6G-d3 (m/z 465.1 → 289.1), morphine (m/z 286.0 → 200.9), and M3G and M6G (m/z 462.1 → 286.1) in the positive ion mode. The method has a linear calibration range from 0.05 to 10 ng for gemfibrozil, morphine, and M3G and M6G with correlation coefficients >0.993. The lower limit of quantitation for all four analytes was 0.05 ng/mL, relative standard deviation of intra- and interday precision was less than 10.5%, and the relative error of accuracy was from -8.2 to 8.3% at low, medium, and high concentrations for all the analytes. In conclusion, gemfibrozil can influence the morphine antinociception after coronary heart disease induced chronic angina by the change in one of morphine metabolites', M3G, distribution in mouse brain.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201600088DOI Listing

Publication Analysis

Top Keywords

gemfibrozil morphine
12
solid-phase extraction
12
mouse brain
8
ultra-high performance
8
performance liquid
8
liquid chromatography
8
chromatography tandem
8
tandem mass
8
mass spectrometry
8
spectrometry deuterated
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!