A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fibrin clot structure is affected by levels of particulate air pollution exposure in patients with venous thrombosis. | LitMetric

Background: Particulate air pollution is a risk factor for cardiovascular diseases and thrombosis. Long-term exposure to particulate matter with a diameter<10μm (PM10) has been associated with an increased risk of venous thrombosis.

Objectives: The aim of this study was to investigate whether or not particulate air pollution alters fibrin clot structure and thus modulates thrombosis risk.

Methods: We investigated fibrin polymerization by turbidity (maximum absorbance mOD), clot structure by confocal microscopy (fibre number per μm) and fibrin pore size by permeability (Ks×10(-10)cm(2)) in 103 patients with deep vein thrombosis and 121 healthy controls, for whom levels of air pollution exposure had been recorded. Exposure groups were defined by mean PM10 concentrations over the 730days before the event.

Results: We found a higher average number of fibres per clot area in patients than controls, but no difference in Ks or fibre thickness. When the two groups were divided into high or low exposure to PM10, a significantly denser fibrin clot network structure with thicker fibres (higher maximum absorbance, p<0.05), decreased permeability (lower Ks value, p<0.05) and higher average fibre numbers per clot area (p<0.05) was observed in patients in the high exposure group compared to those with low exposure. There were no significant differences in fibrin clot structure between the two exposure levels in healthy subjects.

Conclusions: PM10 levels are associated with altered fibrin clot structure in patients with deep vein thrombosis but not in controls, suggesting that air pollution may trigger differences in fibrin clot structure only in patients predisposed to thrombotic disease.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envint.2016.03.030DOI Listing

Publication Analysis

Top Keywords

particulate air
8
air pollution
8
fibrin clot
4
clot structure
4
structure levels
4
levels particulate
4
pollution exposure
4
exposure patients
4
patients venous
4
venous thrombosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!