Background: Using a proper laparoscopic trocar for making a downward rectus sheet tunneling (RSHT) during the implementation of peritoneal dialysis (PD) catheters leads to a longer survival of catheter and less catheter dysfunction. As no specific laparoscopic trocar has been invented for insertion of PD catheters, we designed a new trocar. In this article, we describe specifications of our new invented trocar for the first time. We will describe our experience with it in our patients as well.

Methods: The new stainless steel trocar includes a cannula and a mandarin. The cannula consists of a tube pipe and head. The tube pipe is so long that is proper for rectus sheet tunneling, and its internal diameter is fitted for easy passage of the catheter with its cuffs. The head consists of two steel parts holding a unidirectional plastic valve preventing backflow of the air. The mandarin section includes a sharp shaft and a metal cap. The distal end of the mandarin is an atraumatic conical tip which was designed to make a safe RSHT.

Results: A total of 30 PD catheters were successfully implanted through 30 laparoscopic procedures in 12 males and 18 females (mean age 48.16 ± 14.18 years). All catheters were successfully inserted without any intraoperative complication. Exit-site infection, peri-catheter leakage, and outflow failure were found in two, one, and one patient, respectively. We did not find any inflow failure, catheter malpositioning, migration, or kinking. No other complication was observed during the 1-year follow-up period.

Conclusion: The new designed PD trocar is a proper port for laparoscopic implantation of the peritoneal dialysis catheter. It is a safe and easy handle trocar that helps surgeons to make an appropriate rectus sheath tunneling with minimal complications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-016-4883-0DOI Listing

Publication Analysis

Top Keywords

laparoscopic trocar
12
peritoneal dialysis
12
trocar
8
dialysis catheters
8
proper rectus
8
rectus sheath
8
sheath tunneling
8
rectus sheet
8
sheet tunneling
8
designed trocar
8

Similar Publications

Removal of an incarcerated intrauterine device reaching the serosal surface of the uterus by hysteroscopy alone: a case report.

Front Med (Lausanne)

January 2025

Department of Gynecology and Obstetrics, International Peace Maternity and Child Health Hospital Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Municipal Key Clinical Specialty, Shanghai, China.

Background: An intrauterine device (IUD) is a widely used long-term contraceptive device for family planning. However, the IUD can lead to various complications. Severe complications and remedial measures caused by IUDs have been reported in the literature; however, detailed surgical approaches for safely removing the IUD within the minimum surgical range have rarely been described especially in postmenopausal women.

View Article and Find Full Text PDF

Rare but important gastrointestinal complications after laparoscopic inguinal hernia repair: a single-center experience.

Sci Rep

January 2025

Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, No. 99, Longcheng Street, Xiaodian District, Taiyuan, 030032, Shanxi Province, China.

Transabdominal preperitoneal patch plasty (TAPP) versus total extraperitoneal patch plasty (TEP) are surgical techniques commonly used to treat inguinal hernia. However, studies indicate that both procedures may lead to significant complications, particularly gastrointestinal complications, some of which can be life-threatening. We statistically analyzed the complications caused by adult inguinal hernia patients admitted from 2018 to 2022.

View Article and Find Full Text PDF

Deep learning in surgical process Modeling: A systematic review of workflow recognition.

J Biomed Inform

January 2025

Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin 300384, China; National Demonstration Center for Experimental Mechanical and Electrical Engineering Education (Tianjin University of Technology), China. Electronic address:

Objective: The application of artificial intelligence (AI) in health care has led to a surge of interest in surgical process modeling (SPM). The objective of this study is to investigate the role of deep learning in recognizing surgical workflows and extracting reliable patterns from datasets used in minimally invasive surgery, thereby advancing the development of context-aware intelligent systems in endoscopic surgeries.

Methods: We conducted a comprehensive search of articles related to SPM from 2018 to April 2024 in the PubMed, Web of Science, Google Scholar, and IEEE Xplore databases.

View Article and Find Full Text PDF

Since abdominal adhesion are quite problematic in abdominal and pelvic surgery, the conventional HA/CMC film are commonly used as an anti-adhesive material. However, such types are difficult to be rolled and delivered through the port of laparoscopic surgical devices due to adherence to the laparoscopic port or other parts of the films. To create an anti-adhesion film with more favorable handling properties and anti-adhesive effect, we developed a novel punctate uneven gelatin film (PU GF).

View Article and Find Full Text PDF

Background: Obesity is a growing global health issue, with a prevalence rate of 28.8% in Jordan. Bariatric surgery is the most effective treatment for morbid obesity, yet complications such as postoperative bleeding and leakage remain significant concerns.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!