Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position.

J Card Surg

Division of Cardiovascular and Thoracic Surgery, Department of Surgery, Duke University Medical Center, Durham, North Carolina.

Published: May 2016

Background: Transcatheter valve-in-valve (VIV) procedures are an alternative to standard surgical valve replacement in high risk patients.

Methods: Cases in which a commercially approved transcatheter aortic valve replacement (TAVR) device was used for a nonaortic VIV procedure between November 2013 and September 2015 are reviewed. Clinical, echocardiographic, and procedural details, patient survival, and symptom severity by NYHA class at follow-up were assessed.

Results: All patients were heart-team determined high risk for conventional redo surgery (mean STS PROM = 6.8 ± 2.2%). Five patients underwent VIV replacement in the nonaortic position, four for bioprosthetic mitral valve dysfunction, and one for bioprosthetic tricuspid valve dysfunction. Bioprosthetic failure was due to stenosis in three patients and regurgitation in two others. A balloon-expandable device was used for all patients (Edwards Lifesciences, Irvine, CA, USA). Transcatheter VIV replacement was accomplished by the transapical (mitral) and transfemoral venous (tricuspid) approaches. Median postoperative length of stay was five days (range 3-12). No deaths occurred at a mean follow-up of 21 months. NYHA class at follow-up decreased from class IV at baseline to class I or II for all patients. No paravalvular leaks greater than trivial were encountered. Median mean gradient following mitral replacement was 6.5 mmHg (range 6-13 mmHg), and following tricuspid replacement was 4 mmHg. Postoperative complications included hematuria, epistaxis, acute kidney injury, and atrial fibrillation.

Conclusions: Transcatheter VIV implantation in the nonaortic position for dysfunctional bioprostheses can be performed safely with favorable clinical outcomes using a balloon expandable TAVR device. doi: 10.1111/jocs.12745 (J Card Surg 2016;31:282-288).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5142517PMC
http://dx.doi.org/10.1111/jocs.12745DOI Listing

Publication Analysis

Top Keywords

nonaortic position
12
implantation nonaortic
8
valve replacement
8
high risk
8
tavr device
8
nyha class
8
class follow-up
8
viv replacement
8
valve dysfunction
8
dysfunction bioprosthetic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!