A novel dual imaging probe for in vivo magnetic resonance imaging (MRI) and optical imaging was developed by combining gadolinium (Gd)-chelating MR probe and a near-infrared (NIR) fluorophore, aza-BODIPY (AB; BODIPY = boron-dipyrromethene). This aza-BODIPY-based bimodal contrast agent (AB-BCA) showed a significant fluorescence emission around the NIR range and an enhanced longitudinal relaxivity in MR modality. The probe was easily delivered to phagocytic cells of the innate immune system, together with macrophages and dendritic cells (DCs), and presented high-performance fluorescence and MR imaging without obvious cytotoxicity. For in vivo visualization of AB-BCA using MRI and optical imaging, bone marrow-derived DCs were labeled and injected into the footpad of mice, and labeled DCs were tracked in vivo. We observed the migration of AB-BCA-labeled DCs into the lymph nodes via lymphatic vessels using NIR fluorescence and T1-weighted MR images. This dual-modality imaging probe was used for noninvasive monitoring of DC migration into lymph nodes and could be useful for investigating advanced cellular immunotherapy.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.6b03344DOI Listing

Publication Analysis

Top Keywords

imaging probe
12
dual imaging
8
mri optical
8
optical imaging
8
lymph nodes
8
imaging
7
probe
5
vivo
4
vivo tracking
4
tracking phagocytic
4

Similar Publications

The flow convergence method includes calculation of the proximal isovelocity surface area (PISA) and is widely used to classify mitral regurgitation (MR) with echocardiography. It constitutes a primary decision factor for determination of treatment and should therefore be a robust quantification method. However, it is known for its tendency to underestimate MR and its dependence on user expertise.

View Article and Find Full Text PDF

The reduced dimensionality of thin transition metal dihalide films on single-crystal surfaces unlocks a diverse range of magnetic and electronic properties. However, achieving stoichiometric monolayer islands requires precise control over the growth conditions. In this study, we employ scanning probe microscopy to investigate the growth of MnI on Ag(111) via single-crucible evaporation.

View Article and Find Full Text PDF

Recent studies have reported that monitoring spinal cord perfusion pressure (SCPP) using a pressure probe to measure "intraspinal pressure" (ISP) within the subdural space at the injury site may improve the hemodynamic management of acute spinal cord injury (SCI) patients. This study aimed to investigate, within a pig model of SCI, the relationship between the ISP measured within the subdural space and the "spinal cord pressure" (SCP) measured within the spinal cord itself. Specifically, we sought to characterize the changes to ISP and SCP over time, both rostral and caudal to the injury epicenter, and in relation to native spinal cord morphometry.

View Article and Find Full Text PDF

Microelectronic Structure and Doping Nonuniformity of Phosphorus-Doped CdSeTe Solar Cells.

ACS Appl Mater Interfaces

January 2025

National Renewable Energy Laboratory, Golden, Colorado 80401, United States.

Optimizing group-V doping and Se alloying are two main focuses for advancing CdTe photovoltaic technology. We report on nanometer-scale characterizations of microelectronic structures of phosphorus (P)-doped CdSeTe devices using a combination of two atomic force microscopy-based techniques, namely, Kelvin probe force microscopy (KPFM) and scanning spreading resistance microscopy (SSRM). KPFM on device cross-section images distribution of the potential drop across the device.

View Article and Find Full Text PDF

Mercury(II)-Triggered Targeted and NIR-II Fluorescence/Photoacoustic Imaging Probe for High-Sensitivity Early Diagnosis and Evaluating Drug against Acute Liver and Kidney Injury.

Anal Chem

January 2025

State Key Laboratory of Applied Organic Chemistry and Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, College of Chemistry and Chemical Engineering, Lanzhou University, Gansu, Lanzhou 730000, China.

Mercury ions (Hg) have been found to disrupt the body's antioxidant defense mechanisms, leading to oxidative stress and physiological dysfunction. Early diagnosis and real-time monitoring of Hg fluctuations in organ damage are crucial but limited due to the lack of noninvasive and deep tissue imaging probes. Herein, a Hg-triggered targeted and NIR-II fluorescence/photoacoustic (PA) dual-mode molecular probe (NHG-2) was developed for real-time monitoring Hg fluctuations in Hg-induced acute liver and kidney injury mice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!