Fulminant myocarditis is a rare but fatal serious disease that may cause prolonged native cardiac dysfunction with multiorgan failure despite temporary mechanical circulatory support with percutaneous venoatrial extracorporeal membrane oxygenation (VA-ECMO) or intraaortic balloon pumping (IABP). A 26-year-old man with fulminant myocarditis developed life-threatening multiorgan failure after 8 days support by VA-ECMO and IABP. He was transferred to our institution with prolonged cardiac dysfunction on hospital day 8; massive pulmonary edema developed into severe pulmonary dysfunction. Immediately after admission, VA-ECMO and IABP were switched to a paracorporeal pneumatic left ventricular assist device (LVAD) and right centrifugal ventricular assist device with an ECMO circuit shunting from the right ventricle to the pulmonary artery (RVAD-ECMO). After intensive care focusing on respiratory dysfunction, ECMO was successfully weaned, and the right ventricular assist device was switched to a durable paracorporeal pneumatic right ventricular assist device. The paracorporeal bi-ventricular assist devices were finally replaced with an implantable non-pulsatile LVAD on hospital day 181. Currently, 1 year after discharge, the patient is at home awaiting heart transplantation. Combined LVAD and RVAD-ECMO appear to be useful for resolving severe pulmonary edema due to unnecessarily long VA-ECMO support as well as kidney or liver dysfunction caused by circulatory collapse.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-016-0899-4DOI Listing

Publication Analysis

Top Keywords

assist device
20
ventricular assist
16
fulminant myocarditis
12
bi-ventricular assist
8
cardiac dysfunction
8
multiorgan failure
8
va-ecmo iabp
8
hospital day
8
pulmonary edema
8
severe pulmonary
8

Similar Publications

Autonomous microgrids (ATMG), with green power sources, like solar and wind, require an efficient control scheme to secure frequency stability. The weather and locationally dependent behavior of the green power sources impact the system frequency imperfectly. This paper develops an intelligent, i.

View Article and Find Full Text PDF

Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.

View Article and Find Full Text PDF

EEG-based emotion recognition using multi-scale dynamic CNN and gated transformer.

Sci Rep

December 2024

School of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou, 434100, Hubei, China.

Emotions play a crucial role in human thoughts, cognitive processes, and decision-making. EEG has become a widely utilized tool in emotion recognition due to its high temporal resolution, real-time monitoring capabilities, portability, and cost-effectiveness. In this paper, we propose a novel end-to-end emotion recognition method from EEG signals, called MSDCGTNet, which is based on the Multi-Scale Dynamic 1D CNN and the Gated Transformer.

View Article and Find Full Text PDF

Agriculture 4.0 technologies continue to see low adoption among small and medium-sized farmers, primarily because these solutions often fail to account for the specific challenges of rural areas. In this work, we propose and implement a design methodology to develop a Precision Agriculture solution aimed at assisting farmers in managing water stress in Hass avocado crops.

View Article and Find Full Text PDF

Wearable robots are often powered by elastic actuators, which can mimic the intrinsic compliance observed in human joints, contributing to safe and seamless interaction. However, due to their increased complexity, when compared to direct drives, elastic actuators are susceptible to faults, which pose significant challenges, potentially compromising user experience and safety during interaction. In this article, we developed a fault-tolerant control strategy for torque assistance in a knee exoskeleton and investigated user experience during a walking task while emulating faults.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!