Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Blood pressure rises rapidly upon awakening and maybe responsible, in part, for the increased incidence of myocardial infarction and stroke during the morning hours. The aim of the present study was, therefore, to develop a novel chronotherapeutic formulation of metoprolol tartrate (MT) for night time dosing providing maximum effect in the morning hours. Core tablets contained MT, sodium chloride, lactose, Avicel(®) and starch. Powders were mixed, sieved and directly compressed in to tablets using a single punch tablet machine. Core tablets were then coated with 5 or 10% hydroxypropyl methylcellulose as swelling layer and subsequently outer membrane with the mixture of various ratios of Eudragit(®) RS to RL at different coating levels 5, 10, 15% as semi-permeable water insoluble outer coat by conventional pan-spray method. The best formulation with regard to release behavior was chosen and subjected to further release studies in various rotational speed and pHs. Both lag time and release rate were dependent on the coating levels and the osmotic pressure of dissolution medium. A linear relationship between lag time and outer coating levels was observed. The lag time was prolonged with an increase in the coating levels. Both diffusion and osmotic pumping effect were involved in drug release from the device. Significant increases in drug release behavior was not observed using dissolution medium with various pH and different agitation rates. It was found that the release rate was independent of pH, rotational speed and gastric motility and may not be altered due to changes of pH and peristaltic movement along the GI tract.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4794941 | PMC |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!