Purpose: We aimed to assess corneal biomechanics using the ocular response analyzer in patients with normal-tension glaucoma (NTG), and to evaluate the relationship between corneal biomechanics and visual field loss.
Methods: This was a prospective observational case series including patients with bilateral asymmetric NTG. For all patients, corneal hysteresis (CH), corneal resistance factor (CRF), CH - CRF difference, and central corneal thickness values were matched against the mean deviation (MD) of the visual field and the cup/disc ratio. For paired-eye comparison in each patient, both eyes were categorized into a better-eyes group and a worse-eyes group according to lower and higher corneal-compensated intraocular pressure readings, respectively. Statistical analysis was carried out with the independent-samples Student's t-test, and the level of statistical significance was set at 0.05. Correlation was assessed using Pearson's correlation coefficient.
Results: The study included 240 eyes of 120 patients. CH was inversely proportional to the MD in the visual field (P=0.01). CRF in both eyes was inversely proportional to the MD of the visual field (P=0.01). CH - CRF difference was directly proportional to the MD of the visual field (P=0.01). For paired-eye comparison, lower corneal-compensated intraocular pressure was associated with higher CH, higher CRF, smaller cup/disc ratio, and less deterioration of MD of visual field.
Conclusion: CH, CRF, and CH - CRF are more powerful predictors of NTG progression than central corneal thickness.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4807948 | PMC |
http://dx.doi.org/10.2147/OPTH.S93725 | DOI Listing |
PLoS One
January 2025
Department of Ophthalmology, University of Washington, Seattle, WA, United States of America.
To investigate macula and optic nerve head (ONH) mitochondrial metabolic activity using flavoprotein fluorescence (FPF) in normal, glaucoma suspect (GS), and open-angle glaucoma (OAG) eyes we performed a cross-sectional, observational study of FPF in normal, GS, and OAG eyes. The macula and ONH of each eye was scanned and analyzed with a commercially available FPF measuring device (OcuMet Beacon, OcuSciences Inc., Ann Arbor, MI).
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
January 2025
NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom.
Purpose: To investigate the effect of average intraocular pressure (IOP) on the true rate of glaucoma progression (RoP) in the United Kingdom Glaucoma Treatment Study (UKGTS).
Methods: UKGTS participants were randomized to placebo or Latanoprost drops and monitored for up to two years with visual field tests (VF, 24-2 SITA standard), IOP measurements, and optic nerve imaging. We included eyes with at least three structural or functional assessments (VF with <15% false-positive errors).
Front Public Health
January 2025
Biosecurity, Los Alamos National Laboratory, Los Alamos, NM, United States.
Research typically promotes two types of outcomes (inventions and discoveries), which induce a virtuous cycle: something suspected or desired (not previously demonstrated) may become known or feasible once a new tool or procedure is invented and, later, the use of this invention may discover new knowledge. Research also promotes the opposite sequence-from new knowledge to new inventions. This bidirectional process is observed in geo-referenced epidemiology-a field that relates to but may also differ from spatial epidemiology.
View Article and Find Full Text PDFBackground: In recent years, the increase of the post-transplantation diabetes mellitus (PTDM) after renal transplantation encourages people to do a lot of research on the disease. This paper conducted a bibliometric study on PTDM related literature to explore the risk factors of diabetes after kidney transplantation, as well as the current status, hotspots and development trends of PTDM research, so as to provide reference for researchers in related fields.
Methods: We searched the Web of Science Core Collection (WoSCC) database for PTDM literature from January 1, 1990, to August 20, 2023, and used VOSviewer, CiteSpace, and the R package 'bibliometrix' to do bibliometric analysis.
Atten Percept Psychophys
January 2025
Department of Psychology, Chungnam National University, Daejeon, Republic of Korea.
The issue of whether a salient stimulus in the visual field captures attention in a stimulus-driven manner has been debated for several decades. The attentional window account proposed to resolve this issue by claiming that a salient stimulus captures attention and interferes with target processing only when an attentional window is set wide enough to encompass both the target and the salient distractor. By contrast, when a small attentional window is serially shifted among individual stimuli to find a target, no capture is found.