Background: Image review on computer-based workstations has made film-based review outdated. Despite advances in technology, the lack of portability of digital workstations creates an inherent disadvantage. As such, we sought to determine if the quality of image review on a handheld device is adequate for routine clinical use.
Methods: Six CT/CTA cases and six MR/MRA cases were independently reviewed by three neuroradiologists in varying environments: high and low ambient light using a handheld device and on a traditional imaging workstation in ideal conditions. On first review (using a handheld device in high ambient light), a preliminary diagnosis for each case was made. Upon changes in review conditions, neuroradiologists were asked if any additional features were seen that changed their initial diagnoses. Reviewers were also asked to comment on overall clinical quality and if the handheld display was of acceptable quality for image review.
Results: After the initial CT review in high ambient light, additional findings were reported in 2 of 18 instances on subsequent reviews. Similarly, additional findings were identified in 4 of 18 instances after the initial MR review in high ambient lighting. Only one of these six additional findings contributed to the diagnosis made on the initial preliminary review.
Conclusions: Use of a handheld device for image review is of adequate diagnostic quality based on image contrast, sharpness of structures, visible artefacts and overall display quality. Although reviewers were comfortable with using this technology, a handheld device with a larger screen may be diagnostically superior.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1017/cjn.2016.40 | DOI Listing |
Introduction/purpose: Teleultrasound connects expert point-of-care ultrasound (POCUS) users with remote community and rural sites. Evolving technologies including handheld devices, upgraded image quality, and the ability to transmit over low bandwidth connections increase POCUS education, accessibility, and clinical integration. Potential teleultrasound venues include low-resource settings, prehospital care, and austere environments (high altitudes, microgravity, conflict zones, etc.
View Article and Find Full Text PDFPlant Dis
January 2025
University of California Davis, Cooperative Extension, Napa, California, United States;
The timely detection of viral pathogens in vineyards is a critical aspect of management. Diagnostic methods can be labor-intensive and may require specialized training or facilities. The emergence of artificial intelligence (AI) has the potential to provide innovative solutions for disease detection but requires a significant volume of high-quality data as input.
View Article and Find Full Text PDFDisabil Rehabil
January 2025
Sydney School of Health Sciences, Faculty of Medicine & Health, The University of Sydney, Sydney, Australia.
Purpose: To investigate potential mechanisms of a digital rehabilitation intervention associated with improved mobility among adults undertaking rehabilitation.
Materials And Methods: Causal mediation analysis of the AMOUNT trial (ACTRN12614000936628). Participants were randomised to digitally-enabled rehabilitation (virtual reality video games, activity monitors, and handheld computer devices prescribed by a physiotherapist) and usual care or usual care alone.
J Clin Med
January 2025
Primary and Community Care, Ciudad Rodrigo, 37007 Salamanca, Spain.
: Chronic obstructive pulmonary disease (COPD) is a frequent but underdiagnosed disease, primarily due to the lack of access to forced spirometry (FS) in primary care. Portable, easy-to-use expiratory flow meters like Piko-6 and COPD-6 that measure FEV, FEV, and FEV/FEV ratio provide an alternative. Given that Piko-6 and COPD-6 devices measure FEV but not FVC, the aim of the study is to determine the optimal cutoff value for the FEV/FEV ratio of each device to avoid false negatives when these devices are used for COPD screening in primary care (PC).
View Article and Find Full Text PDFInt J Environ Res Public Health
January 2025
Department of Learning Health Sciences, University of Michigan Medical School, Ann Arbor, MI 48109, USA.
Background: Neonatal jaundice (NNJ) remains a leading cause of newborn mortality in much of sub-Saharan Africa. We sought to examine the validity of using a hand-held icterometer as a screening tool to determine which newborns need further assessment. Additionally, we sought to assess the feasibility of its use among mothers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!