ISSLS Prize Winner: Vibration Really Does Disrupt the Disc: A Microanatomical Investigation.

Spine (Phila Pa 1976)

Experimental Tissue Mechanics Laboratory, Department of Chemical and Materials Engineering, University of Auckland, New Zealand.

Published: August 2016

Study Design: Microstructural investigation of vibration-induced disruption of the flexed lumbar disc.

Objective: The aim of the study was to explore micro-level structural damage in motion segments subjected to vibration at subcritical peak loads.

Summary Of Background Data: Epidemiological evidence suggests that cumulative whole body vibration may damage the disc and thus play an important role in low back pain. In vitro investigations have produced herniations via cyclic loading (and cyclic with added vibrations as an exacerbating exposure), but offered only limited microstructural analysis.

Methods: Twenty-nine healthy mature ovine lumbar motion segments flexed 7° and subjected to vibration loading (1300 ± 500 N) in a sinusoidal waveform at 5 Hz to simulate moderately severe physiologic exposure. Discs were tested either in the range of 20,000 to 48,000 cycles (medium dose) or 70,000 to 120,000 cycles (high dose). Damaged discs were analyzed microstructurally.

Results: There was no large drop in displacement over the duration of both vibration doses indicating an absence of catastrophic failure in all tests. The tested discs experienced internal damage that included delamination and disruption to the inner and mid-annular layers as well as diffuse tracking of nucleus material, and involved both the posterior and anterior regions. Less frequent tearing between the inner disc and endplate was also observed. Annular distortions also progressed into a more severe form of damage, which included intralamellar tearing and buckling and obvious strain distortion around the bridging elements within the annular wall.

Conclusion: Vibration loading causes delamination and disruption of the inner and mid-annular layers and limited diffuse tracking of nucleus material. These subtle levels of disruption could play a significant role in initiating the degenerative cascade via micro-level disruption leading to cell death and altered nutrient pathways.

Level Of Evidence: 5.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0000000000001594DOI Listing

Publication Analysis

Top Keywords

motion segments
8
subjected vibration
8
play role
8
vibration loading
8
damage included
8
delamination disruption
8
disruption inner
8
inner mid-annular
8
mid-annular layers
8
diffuse tracking
8

Similar Publications

Skipping represents a training alternative to running due to its lower knee contact forces and higher whole-body metabolic cost. The increased metabolic cost of skipping is associated with a higher vertical center-of-mass (COM) displacement during the support and flight phases of the skipping hop compared to running. However, skipping has lower muscle force impulses than running.

View Article and Find Full Text PDF

Accuracy of full arch scans performed with nine different scanning patterns- an in vitro study.

Clin Oral Investig

January 2025

Department of Prosthetic Dentistry, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.

Objective: Evaluation of the accuracy of direct digitization of maxillary scans depending on the scanning strategy.

Materials And Methods: A maxillary model with a metal bar as a reference structure fixed between the second molars was digitized using the CEREC Primescan AC scanner (N = 225 scans). Nine scanning strategies were selected (n = 25 scans per strategy), differing in scan area segmentation (F = full jaw, H = half jaw, S = sextant) and scan movement pattern (L = linear, Z = zig-zag, C = combined).

View Article and Find Full Text PDF

Computational modeling of cardiac hemodynamics including chordae tendineae, papillaries, and valves dynamics.

Comput Biol Med

January 2025

LaBS, Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy. Electronic address:

In the context of dynamic image-based computational fluid dynamics (DIB-CFD) modeling of cardiac system, the role of sub-valvular apparatus (chordae tendineae and papillary muscles) and the effects of different mitral valve (MV) opening/closure dynamics, have not been systemically determined. To provide a partial filling of this gap, in this study we performed DIB-CFD numerical experiments in the left ventricle, left atrium and aortic root, with the aim of highlighting the influence on the numerical results of two specific modeling scenarios: (i) the presence of the sub-valvular apparatus, consisting of chordae tendineae and papillary muscles; (ii) different MV dynamics models accounting for different use of leaflet reconstruction from imaging. This is performed for one healthy subject and one patient with mitral valve regurgitation.

View Article and Find Full Text PDF

Quantitative and Visual Benefits of Data-Driven Motion Correction on Oncologic PET/CT: A Prospective Cross-sectional Study.

Acad Radiol

January 2025

Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St. Louis, MO 63110 (S.I., M.A.T., M.I., C.S., R.L., A.H., R.L.W., T.J.F.). Electronic address:

Rationale And Objective: Conventional positron emission tomography (PET) respiratory gating utilizes a fraction of acquired PET counts (i.e., optimal gate [OG]), whereas elastic motion correction with deblurring (EMCD) utilizes all PET counts to reconstruct motion-corrected images without increasing image noise.

View Article and Find Full Text PDF

The advancement of neural radiance fields (NeRFs) has facilitated the high-quality 3D reconstruction of complex scenes. However, for most NeRFs, reconstructing 3D tissues from endoscopy images poses significant challenges due to the occlusion of soft tissue regions by invalid pixels, deformations in soft tissue, and poor image quality, which severely limits their application in endoscopic scenarios. To address the above issues, we propose a novel framework to reconstruct high-fidelity soft tissue scenes from low-quality endoscopic images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!