Introduction: Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure.

Materials And Methods: The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures.

Results: A significant difference in the pressure produced using different impression materials was found (P < 0.001). Light body vinyl polysiloxane produced significantly lesser pressure than zinc oxide eugenol impression materials. The presence of relief did affect the magnitude of pressure at various locations.

Conclusion: All impression materials produced pressure during maxillary edentulous impression making. Tray modification is an important factor in changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure.

Clinical Implication: Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4792057PMC
http://dx.doi.org/10.4103/0976-237X.177108DOI Listing

Publication Analysis

Top Keywords

impression materials
28
pressure
14
minimal pressure
12
light body
12
impression
11
oral analog
8
custom trays
8
denture bearing
8
bearing tissues
8
pressure technique
8

Similar Publications

Aims And Background: Competency-based medical education has been widely accepted across the globe and it has been adopted in the undergraduate curriculum in India from 2019. One introduction to this curriculum is the Electives postings. Electives are chosen by the students.

View Article and Find Full Text PDF

Objective: Due to their consistent and individualistic patterns, palatal rugae (PR) are used in forensic dentistry as an ancillary method for personal identification. This study aimed to compare the impression of the PR obtained with the classic alginate impression and casting of the plaster model with the impression of the palate made with an intraoral scanner. Both impressions were compared with each other and with the photograph of the palatal rugae.

View Article and Find Full Text PDF

Purpose: This study aimed to compare different treatment modalities to correct ill-fitted maxillary complete denture either by the conventional relining method or by scanning the relining impression and digitally construct a new denture regarding patient satisfaction, denture retention, and adaptation.

Materials And Methods: Twelve edentulous patients suffering from loose maxillary complete dentures were selected, dentures' borders and fitting surfaces were prepared, and relining impressions were taken, the impressions were scanned and the STL files were used for CAD/CAM milling ( computer aided designing/ computer aided manufacturing) of new maxillary dentures (Group A), then the relining impression went through the conventional laboratory steps to fabricate (Group B) maxillary dentures. Both groups were evaluated regarding patient satisfaction by a specially designed questionnaire, retention values were measured by a digital force gauge at denture insertion appointment and two weeks later, geomagic software was used to evaluate dentures adaptation to oral tissues.

View Article and Find Full Text PDF

Background: Endobronchial ultrasound guided Transbronchial Needle Aspiration (EBUS-TBNA) is the predominant method for investigation of centrally located solitary pulmonary nodules. The method is associated with good to excellent diagnostic sensitivity and specificity with the positive predictive value of the test reaching 100% and reported negative predictive values for FNA of pulmonary nodules ranging from 53% to 97%. The impact of correlating cytologic results with imaging and clinical findings for improvement of negative predictive value has been poorly studied.

View Article and Find Full Text PDF

Purpose: The study was performed to examine the error associated with image superimposition when computed tomography (CT) images of the dental region are substituted with dental scan data, according to the block-out material used in dental impressions.

Materials And Methods: A typodont model was created by bonding orthodontic brackets to teeth on plaster dental stones using melted dental base-plate wax. In the experiment, 2 groups were compared: one using wax and the other using putty as the block-out material to prevent tearing of the impression material during the acquisition of dental impressions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!