A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Right ventricular afterload sensitivity dramatically increases after left ventricular assist device implantation: A multi-center hemodynamic analysis. | LitMetric

Background: Right ventricular (RV) failure is a source of morbidity and mortality after left ventricular assist device (LVAD) implantation. In this study we sought to define hemodynamic changes in afterload and RV adaptation to afterload both early after implantation and with prolonged LVAD support.

Methods: We reviewed right heart catheterization (RHC) data from participants who underwent continuous-flow LVAD implantation at our institutions (n = 244), excluding those on inotropic or vasopressor agents, pulmonary vasodilators or additional mechanical support at any RHC assessment. Hemodynamic data were assessed at 5 time intervals: (1) pre-LVAD (within 6 months); (2) early post-LVAD (0 to 6 months); (3) 7 to 12 months; (4) 13 to 18 months; and (5) very late post-LVAD (18 to 36 months).

Results: Sixty participants met the inclusion criteria. All measures of right ventricular load (effective arterial elastance, pulmonary vascular compliance and pulmonary vascular resistance) improved between the pre- and early post-LVAD time periods. Despite decreasing load and pulmonary artery wedge pressure (PAWP), RAP remained unchanged and the RAP:PAWP ratio worsened early post-LVAD (0.44 [0.38, 0.63] vs 0.77 [0.59, 1.0], p < 0.001), suggesting a worsening of RV adaptation to load. With continued LVAD support, both RV load and RAP:PAWP decreased in a steep, linear and dependent manner.

Conclusions: Despite reducing RV load, LVAD implantation leads to worsened RV adaptation. With continued LVAD support, both RV afterload and RV adaptation improve, and their relationship remains constant over time post-LVAD. These findings suggest the RV afterload sensitivity increases after LVAD implantation, which has major clinical implications for patients struggling with RV failure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4956565PMC
http://dx.doi.org/10.1016/j.healun.2016.01.1225DOI Listing

Publication Analysis

Top Keywords

lvad implantation
16
early post-lvad
12
afterload sensitivity
8
left ventricular
8
ventricular assist
8
assist device
8
afterload adaptation
8
months months
8
pulmonary vascular
8
continued lvad
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!