A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Joint capsule attachment to the coronoid process of the ulna: an anatomic study with implications regarding the type 1 fractures of the coronoid process of the O'Driscoll classification. | LitMetric

Background: The attachment of the anterior joint capsule on the ulnar coronoid process is not yet completely understood. The purpose of this study was to clarify the anatomic relationship between the anterior capsule of the elbow joint and the tip of the coronoid process.

Methods: Seventeen embalmed elbows were used for this anatomic study. The anterior capsule of the elbow joint was reflected, and the attachment of the capsule on the coronoid process was exposed. The attachment of the joint capsule on the coronoid process was macroscopically and histologically observed, its relationship to the coronoid tip was assessed, and the length of the attachment of the joint capsule was measured.

Results: The length of the capsule attachment at the radial side of the coronoid (11.9 mm) was greater than that at the ulnar side (6.1 mm). The bone thickness on the coronoid tip from the proximal edge of the joint capsule attachment was 1.9 mm; together, the cartilage and bone thickness was 4.7 mm. At the radial side of the coronoid, the thickness of the joint capsule at the proximal aspect of the attachment of 2 samples was 0.6 mm and 0.3 mm, and that at the tip of the coronoid was 2.6 mm and 1.7 mm, respectively.

Conclusions: The anterior capsule of the elbow joint had a substantial attachment on the radial side of the coronoid process. The subtype 2 tip fractures of the O'Driscoll classification included the joint capsule attachment, joint cartilage, and subchondral bone.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2016.01.024DOI Listing

Publication Analysis

Top Keywords

joint capsule
28
coronoid process
24
capsule attachment
16
coronoid
12
anterior capsule
12
capsule elbow
12
elbow joint
12
attachment joint
12
radial side
12
side coronoid
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!