Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The stackable and submergible microbial fuel cell (SS-MFC) system was fabricated consisting of three MFC modules (#1, #2 and #3) that were immersed in an anaerobic tank as a 30 L anode compartment. Each module consisted of the anion exchange membrane-membrane electrode assembly (A-MEA) and cation exchange membrane-MEA (C-MEA). Two MEAs shared a cathode compartment in the module and the three modules shared a anode compartment The SS-MFC system was operated with two phase. After batch feeding (phase I), the system was operated under continuous mode (phase II) with different organic concentrations (from 50 to 1000 mg/L) and different hydraulic retention times (HRT; from 3.4 to 7.2 h). The SS-MFC system successfully produced a stable voltage. A-MEA generated a lower power density than the C-MEA because of the former's high activation and resistance loss. C-MEA showed a higher average maximum power density (3.16 W/m(3)) than A-MEA (2.82 W/m(3)) at 70 mL/min (HRT of 7.2 h). The current density increased as the organic concentration was increased from 70 to 1000 mg/L in a manner consistent with Monod kinetics. When the HRT was increased from 3.4 to 7.2 h, the power densities of the C-MEAs increased from 34.3-40.9 to 40.7-45.7 mW/m(2), but those of the A-MEAs decreased from 25.3-48.0 to 27.7-40.9 mW/m(2). Although power generation was affected by HRT, organic concentrations, and separator types, the proposed SS-MFC modules can be applied to existing wastewater treatment plants.