Performance improvement and patient safety program-guided quality improvement initiatives can significantly reduce computed tomography imaging in pediatric trauma patients.

J Trauma Acute Care Surg

From the Division of Trauma, Critical Care, and Acute Care Surgery, Department of Surgery (C.R.C., J.D.Y., L.E.E., P.E.B., P.M.K.B., M.A.S., J.M.W.), Oregon Health & Science University, Portland, Oregon; Division of Pediatric Surgery, Department of Surgery (K.S.A., M.A.J.), Oregon Health & Science University, Portland, Oregon; Doernbecher Children's Hospital, Randall Children's Hospital (M.A.J.), Oregon Health & Science University, Portland, Oregon.

Published: August 2016

Background: Morbidity and mortality of cervical spine (C-spine) injury in pediatric trauma patients are high, necessitating quick and accurate diagnosis. Best practices emphasize minimizing radiation exposure through decreased reliance on computed tomography (CT), instead using clinical assessment, physical examination, and alternate imaging techniques. We implemented an institutional performance improvement and patient safety (PIPS) program initiative for C-spine clearance in 2010 because of high rates of CT scans among pediatric trauma patients.

Methods: A retrospective review of pediatric trauma patients, aged 0 years to 14 years, in the pre- and post-PIPS implementation periods was conducted. Rates of C-spine CT, overall CT, other imaging modalities, radiation exposure, patient characteristics, and injury severity were compared, and compliance with PIPS protocol was reviewed.

Results: Patient characteristics and injury severity were similar before and after PIPS implementation. C-spine CT rates decreased significantly between groups (30% vs. 13%, p < 0.001), whereas C-spine plain x-ray rates increased significantly (7% vs. 25%, p < 0.001). There was no difference in C-spine magnetic resonance imaging between groups (12% vs. 10%, p = 0.11). In 2007, 71% of patients received a CT scan for any reason. However, the overall CT rate decreased significantly between groups (60% vs. 45%, p < 0.001). There was an estimated 22% decrease in lifetime attributable risk (LAR) for any cancer due to ionizing imaging exposure in males and 38% decrease in females between the pre- and post-PIPS groups. There was a 54% decrease in LAR for thyroid cancer in males and females between groups; 2014 compliance with the protocol was excellent (82-90% per quarter).

Conclusions: Performance improvement and patient safety program-generated protocol can significantly decrease ionizing radiation exposure. We demonstrate that a simple protocol focused on C-spine imaging has high compliance, decreased C-spine CT scans, and decreased LAR for thyroid cancer. A secondary benefit is a reduction in total CT imaging, with an associated decrease in LAR for all cancers.

Level Of Evidence: Therapeutic study, level IV; diagnostic study, level III.

Download full-text PDF

Source
http://dx.doi.org/10.1097/TA.0000000000001071DOI Listing

Publication Analysis

Top Keywords

pediatric trauma
16
performance improvement
12
improvement patient
12
patient safety
12
trauma patients
12
radiation exposure
12
computed tomography
8
c-spine
8
pre- post-pips
8
c-spine imaging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!