This paper describes an indigenous method for development and deployment of rechargeable liquid filled phantom with newly proposed radionuclide (141)Ce for determination of extrinsic uniformity of gamma cameras. Details about design of phantom, neutron irradiation of cerium targets, chemical processing of (141)Ce, charging of phantom with (141)Ce solution and their performance evaluation are presented. Suitability of (141)Ce in quality assurance of gamma cameras used in in-vivo diagnostic imaging procedures has been amply demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2016.03.014DOI Listing

Publication Analysis

Top Keywords

gamma cameras
12
141ce
5
development phantom
4
phantom assessment
4
assessment 141ce
4
141ce surrogate
4
surrogate radionuclide
4
radionuclide flood
4
flood field
4
field uniformity
4

Similar Publications

CoReSi: a GPU-based software for Compton camera reconstruction and simulation in collimator-free SPECT.

Phys Med Biol

January 2025

CREATIS, INSA de Lyon, Bâtiment Blaise Pascal, 7 Avenue Jean Capelle, Villeurbanne, 69621 Cedex , FRANCE.

Compton cameras are imaging devices that may improve observation of sources of γ photons. We present CoReSi, a Compton Reconstruction and Simulation software implemented in Python and powered by PyTorch to leverage multi-threading and for easy interfacing with image processing and deep learning algorithms. The code is mainly dedicated to medical imaging and for near-field experiments where the images are reconstructed in 3D.

View Article and Find Full Text PDF

Novel photopeak-independent correction method for internal activity calculation of 99mTc: a simulation study.

Radiat Prot Dosimetry

December 2024

Facultad de Medicina, Universidad Autónoma del Estado de México, Paseo Tollocan s/n esquina Jesús Carranza, Col. Moderna de la Cruz, Toluca 50180, Estado de México, Mexico.

This paper presents a new method for correcting the contribution of scattered radiation to the measurement of 99mTc internal activity in nuclear medicine patients using gamma cameras. So, this study aims to derive scattering correction factors by Monte Carlo simulation for anterior and posterior count rates (${I}_{\mathrm{A}}$ and ${I}_{\mathrm{P}}$) in the conjugate view method, enabling more precise estimation of activity A(t) compared to traditional trapezoidal and triangular approximations. The new approach eliminates the need to use photopeak for determining the fraction of scattered photons.

View Article and Find Full Text PDF

Recent Progress in Myocardial Perfusion Imaging Techniques.

Nucl Med Mol Imaging

December 2024

Department of Nuclear Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.

Article Synopsis
  • Nuclear cardiology has advanced rapidly, particularly in myocardial perfusion imaging (MPI) since the 1970s, which is vital for assessing and managing coronary artery disease.
  • Recent innovations include the development of gamma cameras with cadmium zinc telluride (CZT) systems and enhancements in software, as well as ongoing studies into new radiopharmaceuticals for positron emission tomography (PET)-MPI.
  • Despite these advancements, challenges like high equipment and examination costs, along with limited accessibility, pose significant barriers to the practical use of these technologies in nuclear medicine.
View Article and Find Full Text PDF

Background: Pre-clinical studies demonstrate that delivering a high dose at a high dose rate result in less toxicity while maintaining tumor control, known as the FLASH effect. In proton therapy, clinical trials have started using 250 MeV transmission beams and more trials are foreseen. A novel aspect of FLASH treatments, compared to conventional radiotherapy, is the importance of dose rate next to dose and geometry.

View Article and Find Full Text PDF

Thyroid scintigraphy of healthy cats using small-field-of-view gamma cameras.

Front Vet Sci

October 2024

Laboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Republic of Korea.

Introduction: Small-field-of-view (SFOV) gamma cameras can offer higher sensitivities than conventional gamma cameras. However, there are currently no reports on the efficacy and safety of thyroid scintigraphy using SFOV gamma cameras in veterinary medicine. Therefore, we aimed to evaluate the efficacy and radiation safety of an SFOV gamma camera for feline thyroid scintigraphy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!