Background: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2014 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers.

Methods: The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards.

Results: PM Registry: data about 24 680 PM implantations were collected (19 480 first implant and 5200 replacements). The number of collaborating centers was 208. Median age of treated patients was 81 years (75 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 45.3% of first PM implants, sick sinus syndrome in 23.1%, atrial fibrillation plus bradycardia in 11.7%, other in 19.9%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (22.7% of first implants). Use of single-chamber PMs was reported in 26.9% of first implants, of dual-chamber PMs in 63.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.7%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 7.8%. ICD Registry: data about 17 116 ICD implantations were collected (11 274 first implants and 5842 replacements). The number of collaborating centers was 424. Median age of treated patients was 71 years (62 quartile I; 77 quartile III). Primary prevention indication was reported in 72.3% of first implants, secondary prevention in 27.7% (cardiac arrest in 10.1%). A single-chamber ICD was used in 32.2% of first implants, dual-chamber in 37.1% and biventricular in 30.7%.

Conclusions: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a large use of prophylactic and biventricular ICD, reflecting a favorable adherence to trials and guidelines in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1714/2174.23494DOI Listing

Publication Analysis

Top Keywords

icd registry
16
icd
9
pacemaker implantable
8
implantable cardioverter-defibrillator
8
registry
8
registry italian
8
italian association
8
association arrhythmology
8
arrhythmology cardiac
8
demographics clinical
8

Similar Publications

Background And Objective: Despite significant investments in the normalization and the standardization of Electronic Health Records (EHRs), free text is still the rule rather than the exception in clinical notes. The use of free text has implications in data reuse methods used for supporting clinical research since the query mechanisms used in cohort definition and patient matching are mainly based on structured data and clinical terminologies. This study aims to develop a method for the secondary use of clinical text by: (a) using Natural Language Processing (NLP) for tagging clinical notes with biomedical terminology; and (b) designing an ontology that maps and classifies all the identified tags to various terminologies and allows for running phenotyping queries.

View Article and Find Full Text PDF

Background: Lung cancer (LC) represents the leading cause of cancer-related deaths in the Czech Republic. Over the past decade, there have been notable advancements in LC treatment based on findings from controlled clinical trials (CTs). However, patients enrolled in CTs may not fully represent the diversity of real-world patient populations from routine clinical practice.

View Article and Find Full Text PDF

Sudden cardiac death (SCD) remains a major global health concern and represents one of the most common causes of mortality due to cardiovascular diseases. The wearable cardioverter-defibrillator (WCD) is an innovative, non-invasive medical device designed to provide continuous heart monitoring and immediate defibrillation in patients at risk for SCD. The study aimed to assess the efficacy of WCD usage in patients awaiting decision on therapy with implantable cardioverter-defibrillators (ICDs).

View Article and Find Full Text PDF

Perspective: Incidence of Clinician-Diagnosed Lyme Disease in Manitoba, Canada 2009-2018.

Vector Borne Zoonotic Dis

January 2025

Infectious Diseases and Vaccine Programs Branch, Public Health Agency of Canada, Saint-Hyacinthe, Canada.

Article Synopsis
  • Lyme disease (LD) surveillance in Manitoba faces challenges, including underreporting, which affects the understanding of disease trends and distribution.
  • A retrospective analysis from 2009 to 2018 identified 1,658 clinician-diagnosed LD cases from over 1.6 million registrants, with the majority occurring during peak tick activity (May to July).
  • Annualized findings revealed a mean incidence of 10.17 cases per 100,000 people, significantly higher than the 30 cases reported by the Manitoba Health surveillance system, highlighting the extent of underreporting.
View Article and Find Full Text PDF

The aim of this registry-based cohort study was to quantify the prevalence, injury characteristics, and outcomes of alcohol exposure in burn-related injuries. All patients ≥ 18 years presenting to The Alfred Emergency & Trauma Centre, a major trauma centre in Victoria, Australia between January 1, 2019 and December 31, 2022 and included in the Victorian Adult Burns Service registry were included. An explicit chart review was performed to verify retrieved data with alcohol exposure coded when documented in medical records, laboratory evidence of a blood alcohol concentration > 2mmol/L, or recorded in discharge ICD-10-AM codes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!