Background: We hypothesized that exhaled acetone concentration (EAC), reflecting altered blood ketone body metabolism and increased acetone exhaust because of pulmonary congestion in heart failure (HF), would correlate with hemodynamic parameters in patients with non-ischemic chronic HF.
Methods and results: We prospectively enrolled 102 non-ischemic HF patients with New York Heart Association (NYHA) class I-III. Exhaled breath was collected after an overnight fast. Echocardiography and cardiac catheterization were performed in all patients. We also enrolled 17 control patients without HF. EAC in the HF patients was significantly higher than that in the control patients (median EAC; 0.53 vs. 0.38 ppm, P=0.012). EAC positively correlated with blood total ketone bodies (r=0.454, P<0.001), NYHA class (r=0.489, P<0.001), and plasma B-type natriuretic peptide (r=0.316, P=0.001). Right heart catheterization revealed that EAC significantly correlated with pulmonary capillary wedge pressure (PCWP, r=0.377, P<0.001). Receiver-operating characteristic analysis revealed that EAC >1.05 ppm was associated with PCWP ≥18 mmHg (area under the curve [AUC] 0.726, sensitivity 50%, specificity 89%). EAC was shown to be a comparable diagnostic biomarker for HF to BNP (AUC 0.760, sensitivity 80%, specificity 70%).
Conclusions: EAC may be a novel noninvasive biomarker that correlates hemodynamic severity in non-ischemic chronic HF. (Circ J 2016; 80: 1178-1186).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1253/circj.CJ-16-0011 | DOI Listing |
Analyst
January 2025
Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
As a marker of human metabolism, acetone is important for lipid metabolism monitoring and early detection of diabetes. In this study, we developed a handheld biosensor for acetone based on fluorescence detection by utilizing the enzymatic reaction of secondary alcohol dehydrogenase (S-ADH) with β-nicotinamide adenine dinucleotide (NADH, = 340 nm, = 490 nm). In the reaction, NADH is oxidized when acetone is reduced to 2-propanol by S-ADH, and the acetone concentration can be measured by detecting the amount of NADH consumed in this reaction.
View Article and Find Full Text PDFACS Sens
January 2025
Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, India.
Human breath gas analysis is a noninvasive disease diagnostic approach used to identify different pathological conditions in the human body. Monitoring breath acetone (CHO) and ammonia (NH) as biomarkers is vital in diagnosing diabetes mellitus and liver disorders, respectively. In this article, the quartz-enhanced photoacoustic spectroscopy (QEPAS) technique is proposed and demonstrated for measuring CHO and NH in human exhaled breath samples.
View Article and Find Full Text PDFACS Sens
December 2024
Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Republic of Korea.
The increasing prevalence of obesity and metabolic disorders has created a significant demand for personalized devices that can effectively monitor fat metabolism. In this study, we developed an advanced breath analyzer system designed to provide real-time monitoring of exercise-induced fat burning by analyzing volatile organic compounds (VOCs) present in both oral and alveolar breath. Acetone in exhaled breath and β-hydroxybutyric acid (BOHB) in the blood are both biomarkers closely linked to the metabolic fat burning process occurring in the liver, particularly after exercise.
View Article and Find Full Text PDFBiosens Bioelectron
March 2025
International School of Engineering (ISE), Biomedical Materials and Devices for Revolutionary Integrative Systems Engineering Research Unit, Chulalongkorn University, Bangkok, 10330, Thailand. Electronic address:
This work presents a ZnO-coated no-core optical fiber sensor (OFS) designed for the highly sensitive detection of acetone vapor. Acetone is a key biomarker for diabetes, which is linked to blood glucose levels and can be detected non-invasively through breath analysis. The OFS utilizes a no-core fiber (NCF) as the sensing region, coated with a thin layer of ZnO nanoparticles to enhance evanescent field interaction with the VOCs at the fiber interface.
View Article and Find Full Text PDFAnal Chem
December 2024
Department of Biomedical Devices and Instrumentation, Laboratory for Biomaterials and Bioengineering, Institute of Integrated Research, Institute of Science Tokyo, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
Acetone gas in exhaled breath and skin gas is produced when fatty acids are used as an energy source in the body. The selective and sensitive continuous measurement of acetone gas would be useful for the early screening of diabetes mellitus, a condition characterized by increased fatty acid metabolism. In particular, there is a growing need for acetone gas sensors that enable the wearable measurement of trace concentrations of acetone gas emitted through the skin.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!