Aims: The number of cardiovascular implantable electronic devices has increased progressively, leading to an increased need for transvenous lead extraction (TLE) due to device infections. Previous studies described 'ghost' as a post-removal, new, tubular, mobile mass detected by echocardiography following the lead's intracardiac route in the right-sided heart chambers, associated with diagnosis of cardiac device-related infective endocarditis. We aimed to analyse the association between 'ghosts' assessed by transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE) and mortality in patients undergoing TLE.

Methods And Results: We prospectively enrolled 217 patients (70 ± 13 years; 164 males) undergoing TLE for systemic infection (139), local device infection (67), and lead malfunction (11). All patients underwent TEE before and 48 h after TLE and ICE during TLE. Patients were allocated to two groups: either with (Group 1) or without (Group 2) post-procedural 'ghost'. Mid-term clinical follow-up was obtained in all patients (11 months, IQR 1-34 months). We identified 30 (14%) patients with 'ghost', after TLE. The significant predictors of 'ghost' were Charlson co-morbidity index (HR = 1.24, 95% CI 1.04-1.48, P = 0.03) and diagnosis of endocarditis assessed by ICE (HR = 1.82, 95% CI 1.01-3.29, P = 0.04). Mortality was higher in Group 1 than in Group 2 (28 vs. 5%; log-rank P < 0.001). Independent predictors of mid-term mortality were the presence of 'ghost' and systemic infection as the clinical presentation of device infection (HR = 3.47, 95% CI 1.18-10.18, P = 0.002; HR = 3.39, 95% CI 1.15-9.95, P = 0.001, respectively).

Conclusion: The presence of 'ghost' could be an independent predictor of mortality after TLE, thus identifying a subgroup of patients who need closer clinical surveillance to promptly detect any complications.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euw045DOI Listing

Publication Analysis

Top Keywords

transvenous lead
8
lead extraction
8
systemic infection
8
device infection
8
group group
8
presence 'ghost'
8
patients
7
tle
6
'ghost'
6
mortality
5

Similar Publications

A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.

View Article and Find Full Text PDF

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.

View Article and Find Full Text PDF

Objective: To compare the paced QRS duration on different sites in age-, gender-, and indication-matched patients implanted with Micra leadless pacemakers and conventional transvenous pacemakers (TV-PM).

Method: A total of 82 patients from Xinhua Hospital, Shanghai Jiaotong University, were enrolled, including two groups of 41 patients matched according to gender, age, and pacemaker indications, who underwent Micra and TV-PM implantations, respectively. The baseline data of the patients, the pacing site described using three- and nine-partition methods, and the paced QRS duration on 12-lead electrocardiogram were then analyzed.

View Article and Find Full Text PDF

Leadless Pacing: Current Status and Ongoing Developments.

Micromachines (Basel)

January 2025

Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.

Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!