Background: Pannus formation may disturb the leaflet movement of the prosthetic valve.
Case Presentation: A 61-year-old woman presented with exertional dyspnea. She had undergone mitral valve replacement with a bioprosthetic valve 31 years ago, which was replaced with a tilting disc valve 22 years ago. The present laboratory findings revealed hemolytic anemia. Echocardiography showed an increased mean pressure gradient through the mitral valve and moderate to severe regurgitation around the minor orifice of the tilting disc valve. She therefore underwent a third operation. Pannus formation was found on the prosthetic valve ring, but it did not obliterate the prosthetic valve orifice. After removing the valve, the posterior wall of the left ventricle was seen to be associated with thickened endocardium. A bileaflet valve was implanted. Postoperative echocardiography showed that the implanted valve functioned well.
Conclusions: Nonstructural dysfunction of the mechanical heart valve might occur long after operation. These changes are particularly observed with a tilting disc valve.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4812606 | PMC |
http://dx.doi.org/10.1186/s13019-016-0436-9 | DOI Listing |
PLoS One
January 2025
Cardiology Department, Vétérinaire Clinic Boulogne Roland Garros, Boulogne Billancourt, France.
Introduction: Aortic stenosis (AS) and pulmonic stenosis (PS) are two of the most common canine congenital heart diseases (CHD), with a high relative risk for Newfoundland dogs to develop inherited subvalvular AS. For this reason, a cardiovascular screening program has been set up by the French Newfoundland kennel club in order to manage mattings and reduce AS prevalence.
Materials And Methods: The records of untreated and non-anesthetized adult Newfoundland dogs screened between 2010 and 2023 were retrospectively reviewed.
Pulmonology
December 2025
Department of Emergency and Intensive Care, Fondazione IRCCS San Gerardo dei tintori, Monza, Italy.
Background: Non-invasive helmet respiratory support is suitable for several clinical conditions. Continuous-flow helmet CPAP systems equipped with HEPA filters have become popular during the recent Coronavirus pandemic. However, HEPA filters generate an overpressure above the set PEEP.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
January 2025
Cardiology, Endeavor NorthShore Cardiovascular Institute, Evanston, IL, USA.
This study aims to evaluate the implementation of concomitant CAD assessment on pre-TAVI (transcatheter aortic valve implantation) planning CTA (CT angiography) aided by CT-FFR (CT-fractional flow reserve) [The CT2TAVI protocol] and investigates the incremental value of CT-FFR to coronary CT angiography (CCTA) alone in the evaluation of patients undergoing CT2TAVI. This is a prospective observational real-world cohort study at an academic health system on consecutive patients who underwent CTA for TAVI planning from 1/2021 to 6/2022. This represented a transition period in our health system, from not formally reporting CAD on pre-TAVI planning CTA (Group A) to routinely reporting CAD on pre-TAVI CTA (Group B; CT2TAVI protocol).
View Article and Find Full Text PDFPediatr Cardiol
January 2025
Department of Cardiovascular Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences and Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, Japan.
We reviewed the outcomes of truncus arteriosus repair (primary vs. staged repair incorporating bilateral pulmonary artery banding), focusing on survival, reintervention, and functional data. We analyzed 39 patients who underwent a first intervention for truncus arteriosus (staged, n = 19; primary, n = 20) between 1992 and 2022.