Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: To compare plan robustness of volumetric modulated arc therapy (VMAT) with intensity modulated radiation therapy (IMRT) and to compare the effectiveness of 3 plan robustness quantification methods.
Methods And Materials: The VMAT and IMRT plans were created for 9 head and neck cancer patients. For each plan, 6 new perturbed dose distributions were computed using ±3 mm setup deviations along each of the 3 orientations. Worst-case analysis (WCA), dose-volume histogram (DVH) band (DVHB), and root-mean-square dose-volume histogram (RVH) were used to quantify plan robustness. In WCA, a shaded area in the DVH plot bounded by the DVHs from the lowest and highest dose per voxel was displayed. In DVHB, we displayed the envelope of all DVHs in band graphs of all the 7 dose distributions. The RVH represents the relative volume on the vertical axis and the root-mean-square-dose on the horizontal axis. The width from the first 2 methods at different target DVH indices (such as D and D) and the area under the RVH curve for the target were used to indicate plan robustness. Results were compared using Wilcoxon signed-rank test.
Results: The DVHB showed that the width at D of IMRT was larger than that of VMAT (unit Gy) (1.59 vs 1.18) and the width at D of IMRT was comparable to that of VMAT (0.59 vs 0.54). The WCA showed similar results between IMRT and VMAT plans (D: 3.28 vs 3.00; D: 1.68 vs 1.95). The RVH showed the area under the RVH curve of IMRT was comparable to that of VMAT (1.13 vs 1.15). No statistical significance was found in plan robustness between IMRT and VMAT.
Conclusions: The VMAT is comparable to IMRT in terms of plan robustness. For the 3 quantification methods, WCA and DVHB are DVH parameter-dependent, whereas RVH captures the overall effect of uncertainties.