A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Can surface imaging improve the patient setup for proton postmastectomy chest wall irradiation? | LitMetric

Can surface imaging improve the patient setup for proton postmastectomy chest wall irradiation?

Pract Radiat Oncol

Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts.

Published: March 2017

Purposes/objectives: For postmastectomy radiation therapy by proton beams, the usual bony landmark based radiograph setup technique is indirect because the target volumes are generally superficial and far away from major bony structures. The surface imaging setup technique of matching chest wall surface directly to treatment planning computed tomography was evaluated and compared to the traditional radiograph-based technique.

Methods And Materials: Fifteen postmastectomy radiation therapy patients were included, with the first 5 patients positioned by standard radiograph-based technique; radiopaque makers, however, were added on the patient's skin surface to improve the relevance of the setup. AlignRT was used to capture patient surface images at different time points along the process, with the calculated position corrections recorded but not applied. For the remaining 10 patients, the orthogonal x-ray imaging was replaced by the AlignRT setup procedure followed by a beamline radiograph at the treatment gantry angle only as confirmation. The position corrections recorded during all fractions for all patients (28-31 each) were analyzed to evaluate the setup accuracy. The time spent on patient setup and treatment delivery was also analyzed.

Results: The average position discrepancy over the treatment course relative to the planning computed tomography was significantly larger in the radiograph only group, particularly in translations (3.2 ± 2.0 mm in vertical, 3.1 ± 3.0 mm in longitudinal, 2.6 ± 2.5 mm in lateral), than AlignRT assisted group (1.3 ± 1.3 mm in vertical, 0.8 ± 1.2 mm in longitudinal, 1.5 ± 1.4 mm in lateral). The latter was well within the robustness limits (±3 mm) of the pencil beam scanning treatment established in our previous studies. The setup time decreased from an average of 11 minutes using orthogonal x-rays to an average of 6 minutes using AlignRT surface imaging.

Conclusions: The use of surface imaging allows postmastectomy chest wall patients to be positioned more accurately and substantially more efficiently than radiograph only-based techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prro.2016.02.001DOI Listing

Publication Analysis

Top Keywords

surface imaging
12
chest wall
12
setup
8
patient setup
8
postmastectomy chest
8
postmastectomy radiation
8
radiation therapy
8
setup technique
8
planning computed
8
computed tomography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!