ZEISS Angioplex™ optical coherence tomography (OCT) angiography generates high-resolution three-dimensional maps of the retinal and choroidal microvasculature while retaining all of the capabilities of the existing CIRRUS™ HD-OCT Model 5000 instrument. Angioplex™ OCT angiographic imaging on the CIRRUS™ HD-OCT platform was made possible by increasing the scanning rate to 68,000 A-scans per second and introducing improved tracking software known as FastTrac™ retinal-tracking technology. The generation of en face microvascular flow images with Angioplex™ OCT uses an algorithm known as OCT microangiography-complex, which incorporates differences in both the phase and intensity information contained within sequential B-scans performed at the same position. Current scanning patterns for en face angiographic visualization include a 3 × 3 and a 6 × 6 mm scan pattern on the retina. A volumetric dataset showing erythrocyte flow information can then be displayed as a color-coded retinal depth map in which the microvasculature of the superficial, deep, and avascular layers of the retina are displayed together with the colors red, representing the superficial microvasculature; green, representing the deep retinal vasculature; and blue, representing any vessels present in the normally avascular outer retina. Each retinal layer can be viewed separately, and the microvascular layers representing the choriocapillaris and the remaining choroid can be viewed separately as well. In addition, readjusting the contours of the slabs to target different layers of interest can generate custom en face flow images. Moreover, each en face flow image is accompanied by an en face intensity image to help with the interpretation of the flow results. Current clinical experience with this technology would suggest that OCT angiography should replace fluorescein angiography for retinovascular diseases involving any area of the retina that can be currently scanned with the CIRRUS™ HD-OCT instrument and may replace fluorescein angiography and indocyanine green angiography for some choroidal vascular diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000442773DOI Listing

Publication Analysis

Top Keywords

cirrus™ hd-oct
12
zeiss angioplex™
8
optical coherence
8
coherence tomography
8
oct angiography
8
angioplex™ oct
8
flow images
8
viewed separately
8
face flow
8
replace fluorescein
8

Similar Publications

Purpose: To characterize the anterior segment (AS) morphology of patients with long-term silicone oil (SiO) in situ (> 12 months) following pars plana vitrectomy (PPV).

Methods: This prospective, comparative characterization study was conducted between January 2022 and July 2023. Patients were included and sorted based on if they had undergone PPV without long-term SiO or had SiO in situ for at least 12 months at the time of review and image collection.

View Article and Find Full Text PDF

Objectives: Various imaging features on optical coherence tomography (OCT) are crucial for identifying and defining disease progression. Establishing a consensus on these imaging features is essential, particularly for training deep learning models for disease classification. This study aims to analyze the inter-rater reliability in labeling the quality and common imaging signatures of retinal OCT scans.

View Article and Find Full Text PDF

Purpose: To evaluate the 6-month progression of retinal capillary perfusion in eyes with advanced stages of nonproliferative diabetic retinopathy (NPDR).

Design: RICHARD (NCT05112445), 2-year prospective longitudinal study.

Participants: Sixty eyes with Diabetic Retinopathy Severity Scale (DRSS) levels 43, 47, and 53 from 60 patients with type 2 diabetes.

View Article and Find Full Text PDF

Purpose: Optical coherence tomography (OCT)-derived measurements of the optic nerve head (ONH) from different devices are not interchangeable. This poses challenges to patient follow-up and collaborative studies. Here, we present a device-agnostic method for the extraction of OCT biomarkers using artificial intelligence.

View Article and Find Full Text PDF

: To evaluate the clinical performance of two optical coherence tomography angiography (OCTA) devices, including a semi-automated device, with respect to image quality and pathology detection, with fluorescein angiography (FA) and indocyanine green angiography (ICGA) serving as the reference standards. : In this prospective cross-sectional study, normal eyes and those with various retinal and choroidal pathologies were enrolled and underwent OCTA scanning using semi-automated 3D OCT-1 Maestro2 and Cirrus™ HD-OCT 5000 devices, as well as FA/ICGA imaging. OCTA scans and FA/ICGA images were independently graded for image quality and the visibility of prespecified anatomic vascular features, along with the presence or absence of pathology on the OCTA scans and the FA/ICGA images (within regions corresponding to the OCTA scan areas).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!