Objective: To analyze the clinical and radiological outcomes from total hip arthroplasty using the Biomec prosthesis over a 20-year period (1988 to 2009).

Methods: The patients were evaluated clinically in accordance with the Merle d'Aubigné and Postel functional classification, and underwent anteroposterior (AP) radiography of the pelvis and the operated joint in lateral view. The variables evaluated were acetabular and femoral osteolysis, polyethylene wear, nail migration, follow-up and clinical outcomes.

Results: The mean follow-up was 10.6 years (range 4 to 21 years). The sample consisted of 84 patients (32 men and 52 women) and the mean preoperative age was 47 years. We found that 88% of the results from the clinical evaluation were good or excellent. In relation to the radiological findings, 92.5% of the results were good. The mean wear on the polyethylene was 1.4 mm.

Conclusion: The use of the Biomec prosthesis in this cohort showed good clinical and radiographic results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799109PMC
http://dx.doi.org/10.1016/S2255-4971(15)30286-XDOI Listing

Publication Analysis

Top Keywords

biomec prosthesis
12
total hip
8
hip arthroplasty
8
arthroplasty biomec
8
prosthesis 20-year
8
20-year follow-up
4
follow-up objective
4
objective analyze
4
clinical
4
analyze clinical
4

Similar Publications

Shape-Setting of Self-Expanding Nickel-Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge.

Cardiovasc Eng Technol

June 2024

Biomechanics Research Centre (BioMEC), School of Engineering and Informatics, University of Galway, Galway, Ireland.

Purpose: Altered hemodynamics caused by the presence of an endovascular device may undermine the success of peripheral stenting procedures. Flow-enhanced stent designs are under investigation to recover physiological blood flow patterns in the treated artery and reduce long-term complications. However, flow-enhanced designs require the development of customised manufacturing processes that consider the complex behaviour of Nickel-Titanium (Ni-Ti).

View Article and Find Full Text PDF

Multi-objective design optimization of bioresorbable braided stents.

Comput Methods Programs Biomed

December 2023

PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy. Electronic address:

Background And Objectives: Bioresorbable braided stents, typically made of bioresorbable polymers such as poly-l-lactide (PLLA), have great potential in the treatment of critical limb ischemia, particularly in cases of long-segment occlusions and lesions with high angulation. However, the successful adoption of these devices is limited by their low radial stiffness and reduced elastic modulus of bioresorbable polymers. This study proposes a computational optimization procedure to enhance the mechanical performance of bioresorbable braided stents and consequently improve the treatment of critical limb ischemia.

View Article and Find Full Text PDF

The objective of this study is to present a credibility assessment of finite element modelling of self-expanding nickel-titanium (Ni-Ti) stents through verification and validation (VV) activities, as set out in the ASME VV-40 standard. As part of the study, the role of calculation verification, model input sensitivity, and model validation is examined across three different application contexts (radial compression, stent deployment in a vessel, fatigue estimation). A commercially available self-expanding Ni-Ti stent was modelled, and calculation verification activities addressed the effects of mesh density, element integration and stable time increment on different quantities of interests, for each context of use considered.

View Article and Find Full Text PDF

The corrosion, mechanical degradation and biological performance of cold-drawn WE43 Mg wires were analyzed as a function of thermo-mechanical processing and the presence of a protective oxide layer created by continuous plasma electrolytic oxidation (PEO). It was found that the corrosion properties of the non-surface-treated wire could be optimized by means of thermal treatment within certain limits, but the corrosion rate remained very high. Hence, strength and ductility of these wires vanished after 24 h of immersion in simulated body fluid at 37 °C and, as a result of that rather quick degradation, direct tests did not show any MC3T3-E1 preosteoblast cell attachment on the surface of the Mg wires.

View Article and Find Full Text PDF

An experimental investigation of the mechanical performance of PLLA wire-braided stents.

J Mech Behav Biomed Mater

February 2023

Biomechanics Research Centre (BioMEC), School of Engineering, College of Science and Engineering, University of Galway, Ireland. Electronic address:

Much of our current understanding of the performance of self-expanding wire-braided stents is based on mechanical testing of Nitinol-based or polymeric non-bioresorbable (e.g. PET, PP etc.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!