A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implementation of NAT Screening for West Nile Virus and Experience with Seasonal Testing in Germany. | LitMetric

Implementation of NAT Screening for West Nile Virus and Experience with Seasonal Testing in Germany.

Transfus Med Hemother

Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany.

Published: January 2016

Background: West Nile virus (WNV) can be transmitted by transfusion through infected blood components. In Germany, a 28-day deferral for blood donors of therapeutic blood components who had spent at least 2 days in WNV-endemic areas from June 1 to November 30, 2014 was enforced. Otherwise, screening of blood donors for WNV RNA or the application of pathogen reduction techniques are appropriate alternatives.

Methods: In the present study, we evaluated NAT screening for the detection of WNV in blood components. A total of 58 minipools consisting of 357 individual blood donors were screened for the presence of WNV RNA employing an automated high-volume extraction method using the RealStar WNV RT-PCR Kit. Additionally, different WNV reference reagents were quantified to prove the status quo of standardization. Four different WNV real-time NAT kits were compared using samples of an external quality assessment panel.

Results: The 95% lower detection limit of the WNV MP-NAT was determined to 30.2 copies/ml (95% CI 24.2-45.4 copies/ml). No WNV RNA-positive minipool was detected. Quantification of WNV reference reagents revealed shortcomings in standardization. Comparison of several WNV NAT assays showed considerable differences in assay sensitivities and particularly a missing detection of WNV lineage 2. Implementation of seasonal WNV MP-NAT screening was demonstrated.

Conclusion: Actually, WNV infections in Germany are rare events introduced by returning travelers, but surveillance of these emerging infections is important for safety in blood supply. The validation study pointed out the need for standardization of WNV NAT because of current lack of an international standard for WNV RNA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4797461PMC
http://dx.doi.org/10.1159/000440833DOI Listing

Publication Analysis

Top Keywords

wnv
16
blood components
12
blood donors
12
wnv rna
12
nat screening
8
west nile
8
nile virus
8
detection wnv
8
wnv reference
8
reference reagents
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!