This study compared the wear characteristics of a heat-pressed lithium disilicate ceramic material opposed to feldspathic porcelain, a lithium disilicate glass ceramic, and zirconia materials. Ceramic plate specimens were prepared from feldspathic porcelain (EX-3 nA1B), lithium disilicate glass ceramics (e.max CAD MO1/C14), and zirconia (Katana KT 10) and then ground or polished. Rounded rod specimens were fabricated from heat-pressed lithium disilicate glass ceramic (e.max press LT A3) and then glazed or polished. A sliding wear testing apparatus was used for wear testing. Wear of glazed rods was greater than that of polished rods when they were abraded with ground zirconia, ground porcelain, polished porcelain, or polished lithium disilicate ceramics. For both glazed and polished rods, wear was greater when the rods were abraded with ground plates. The findings indicate that application of a polished surface rather than a glazed surface is recommended for single restorations made of heat-pressed lithium disilicate material. In addition, care must be taken when polishing opposing materials, especially those used in occlusal contact areas. (J Oral Sci 58, 117-123, 2016).

Download full-text PDF

Source
http://dx.doi.org/10.2334/josnusd.58.117DOI Listing

Publication Analysis

Top Keywords

lithium disilicate
28
heat-pressed lithium
12
disilicate glass
12
wear characteristics
8
polished
8
disilicate ceramics
8
feldspathic porcelain
8
glass ceramic
8
glazed polished
8
wear testing
8

Similar Publications

Purpose: This in-vitro study was conducted to assess the fracture resistance of resin-bonded ceramic endocrowns with different designs at varying intracoronal depths.

Materials And Methods: Forty-eight (n = 48) extracted mandibular first molar teeth were randomly divided into four groups (n = 12). In the control group, the specimens remained untreated.

View Article and Find Full Text PDF

Effect of crystallization temperature on the flexural strength of lithium disilicate glass ceramics.

J Prosthodont

January 2025

Division of Prosthodontics, Department of Restorative Sciences, University of Minnesota, Minneapolis, Minnesota, USA.

Purpose: This pilot study aimed to compare the flexural strength of Amber Mill CAD to IPS e.max CAD and to determine the impact of different crystallization protocols on the flexural strength of Amber Mill CAD ceramics.

Materials And Methods: Amber Mill CAD ceramic blocks of a known Vita Classic shade were selected for testing against control IPS e.

View Article and Find Full Text PDF

Measurement of volumetric wear of printed polymer resin and milled polymer infused ceramic network definitive restorative materials.

J Prosthet Dent

January 2025

Associate Professor and Director of Student Research, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, OH. Electronic address:

Statement Of Problem: Currently there is no regulatory requirement or international standard for the wear resistance of dental materials and therefore no need to test prior to market launch.

Purpose: The purpose of this in vitro study was to evaluate and compare the total volumetric wear characteristics of milled polymer infiltrated ceramic network (MPICN) and printed polymer resin (PPR) as substrates opposing five antagonists, human enamel (EN), lithium disilicate (LD), zirconia (ZR), MPICN, and PPR, and to evaluate and compare the volumetric wear of these same materials as antagonists.

Material And Methods: Ten of each antagonist for a total of 50 EN, LD (IPS e.

View Article and Find Full Text PDF

This study aims to investigate the effects of material compatibility, variable cooling rates, and crown geometry on thermal stress development in porcelain-veneered lithium disilicate (PVLD) and porcelain-veneered zirconia (PVZ) dental crown systems, and subsequently anticipate parameters for their optimum performance. An anatomically correct 3D crown model was developed from STL files generated using 3D scans of the experimental crown sample. Next, the viscoelastic finite element model (VFEM) based on the 3D crown model was developed and validated for anatomically correct bilayer PVLD and PVZ crown systems.

View Article and Find Full Text PDF

Bonding performance of universal adhesive systems with dual-polymerising resin cements to various dental substrates: in vitro study.

BMC Oral Health

January 2025

Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-Ku, Tokyo, 113-8549, Japan.

Background: Resin cements often require substrate-specific pretreatment. Recently, universal adhesive systems have been introduced, simplifying procedures by eliminating the need for multiple adhesives and offering options that do not require light curing. This study investigated the bonding performance of universal adhesive systems combined with dual-polymerising resin cements on enamel, dentin, zirconia, lithium disilicate ceramics (LDS), and resin blocks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!