Purpose: Autograft preparation for anterior cruciate ligament (ACL) reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of bacterial contamination of hamstring autograft during preparation and when dropped onto the operating room floor and methods of graft decontamination.

Methods: Sixty hamstring tendon autograft specimens were used as the test group. Excess tendon not used in the ACL procedure was divided into five segments. One segment, at the completion of preparation, was sent for culture as a control; the remaining four segments were dropped onto the floor adjacent to the surgical field for 15 seconds. One segment was cultured without undergoing any further treatment. Cultures were taken from each segment after immersion in 10 % povidone-iodine solution, 4 % chlorhexidine and bacitracin, respectively, for three minutes. Cultures of a skin swab and floor swab were taken at the same time and place that the ACL was dropped.

Results: Cultures of control graft tissue from ten patients (16.7 %) were positive for bacteria. No patient developed post-operative infection. Ninety organisms were identified, with Staphylococcus epidermidis being the most common isolate. Grafts rinsed in either bacitracin or 4 % chlorhexidine solutions were less likely to be culture positive.

Conclusions: A high rate of contamination can be expected during autograft preparation for ACL reconstruction. Soaking the hamstring autograft in either bacitracin or 4 % chlorhexidine solution is effective for decontamination, particulary if graft is dropped on the floor.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-016-3168-5DOI Listing

Publication Analysis

Top Keywords

autograft preparation
12
4 % chlorhexidine
12
bacterial contamination
8
anterior cruciate
8
cruciate ligament
8
acl reconstruction
8
hamstring autograft
8
dropped floor
8
bacitracin 4 %
8
autograft
5

Similar Publications

Background: A goal of mucosal human immunodeficiency virus type 1 (HIV-1) vaccines is to generate mucosal plasma cells producing polymeric IgA (pIgA)-neutralizing antibodies at sites of viral entry. However, vaccine immunogens capable of eliciting IgA neutralizing antibodies (nAbs) that recognize tier 2 viral isolates have not yet been identified.

Methods: To determine if stabilized native-like HIV-1 envelope (Env) trimers could generate IgA nAbs, we purified total IgA and IgG from the banked sera of six rhesus macaques that had been found in a previous study to develop serum nAbs after subcutaneous immunization with BG505.

View Article and Find Full Text PDF

Innovative Mechanical Processing of Adipose Tissue: A Comparative Evaluation of Microfat and Concentrated Micronized Fat for Superficial Fat Grafting.

Aesthetic Plast Surg

January 2025

Department of Body Contouring and Fat grafting Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No 33 Badachu Road, Shijingshan District, 100144, Beijing, People's Republic of China.

Background: Superficial autologous fat grafting is widely used for facial rejuvenation and regenerative treatments, yet its retention rate remains unpredictable. Enhancing the concentration of adipose-derived stem cells (ASCs) has been shown to improve graft retention. Mechanical fat processing techniques can reduce fat granules size for superficial injection as well as elevate the concentration of ASCs.

View Article and Find Full Text PDF

Purpose: Using a thin semitendinosus tendon as an autograft is a risk factor for poor clinical outcomes after anterior cruciate ligament reconstruction. Preoperative evaluation of the cross-sectional area of the semitendinosus tendon using magnetic resonance imaging is useful. However, studies comparing the cross-sectional area of the semitendinosus tendon on magnetic resonance imaging and the collagen fibril diameter of the semitendinosus tendon are lacking.

View Article and Find Full Text PDF

Unlabelled: Human umbilical cord-derived mesenchymal stromal cells (UC-MSCs), which can be prepared in advance and are presumed to be advantageous for nerve regeneration, have potential as a cell source for Bio 3D conduits. The purpose of this study was to evaluate the nerve regeneration ability of Bio 3D conduits made from UC-MSCs using a rat sciatic nerve defect model.

Methods: A Bio 3D conduit was fabricated using a Bio 3D printer by placing UC-MSC spheroids into thin needles according to predesigned 3D data.

View Article and Find Full Text PDF

Hard-to-heal wounds represent a global and growing medical and economic burden. Skin autografting is a useful treatment option but is often limited by donor site morbidity, logistical considerations, and grafting success in compromised wound beds. Combining autologous skin cell suspension (ASCS) technology with minced dermal grafts can allow for dermal elements and epithelial healing as well as closed donor sites.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!