In order to understand the fracture mechanisms of bone subjected to external force well, an experimental study has been performed on the bovine bone by carrying out the three-point bending test with 3D digital image correlation (DIC) method, which provides a noncontact and full field of displacement measurement. The local strain and damage evolution of the bone has been recorded real time. The results show that the deflection measured by DIC agrees well with that obtained by the displacement sensor of the mechanical testing machine. The relationship between the deflection and the force is nearly linear prior to reaching the peak strength which is about 16 kN for the tested bovine tibia. The full-field strain contours of the bone show that the strain distribution depends on not only the force direction, but also the natural bone shape. The natural arched-shape bovine tibia bone could bear a large force, due to the tissue structure with high strength, and the fracture propagation process of the sample initiates at the inner side of the bone first and propagates along the force direction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4745433PMC
http://dx.doi.org/10.1155/2015/609132DOI Listing

Publication Analysis

Top Keywords

bone
8
bovine bone
8
digital image
8
image correlation
8
bovine tibia
8
force direction
8
force
5
experimental investigation
4
investigation mechanical
4
mechanical behavior
4

Similar Publications

Background: Traumatic anterior shoulder dislocation is the most common type of joint dislocation, with an incidence of 11 to 29 per 100 000 persons per year. Controversy still surrounds the recommendations for treatment and the available procedures for surgical stabilization.

Methods: This review is based on pertinent publications (2014-2024) that were retrieved by a selective search in the PubMed and Google Scholar databases.

View Article and Find Full Text PDF

Micro- and nanomorphological modification and roughening of titanium implant surfaces can enhance osseointegration; however, the optimal morphology remains unclear. Laser processing of implant surfaces has demonstrated significant potential due to its precision, controllability, and environmental friendliness. Femtosecond lasers, through precise optimization of processing parameters, can modify the surface of any solid material to generate micro- and nanomorphologies of varying scales and roughness.

View Article and Find Full Text PDF

Purpose: Orvacabtagene autoleucel (orva-cel; JCARH125), a CAR T-cell therapy targeting B-cell maturation antigen (BCMA), was evaluated in relapsed/refractory multiple myeloma (RRMM) patients in the EVOLVE phase 1/2 study (NCT03430011). We applied a modified piecewise model to characterize orva-cel transgene kinetics and assessed the impact of various covariates on its pharmacokinetics (PK).

Experimental Design: The population PK analysis included 159 patients from the EVOLVE study.

View Article and Find Full Text PDF

Comparative Effectiveness of Individual Sodium-Glucose Cotransporter 2 Inhibitors.

JAMA Intern Med

January 2025

Division of Pharmacoepidemiology and Pharmacoeconomics, Department of Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts.

Importance: Evidence on cardiovascular benefits and safety of sodium-glucose cotransporter 2 (SGLT-2) inhibitors is mainly from placebo-controlled trials. Therefore, the comparative effectiveness and safety of individual SGLT-2 inhibitors remain unknown.

Objective: To compare the use of canagliflozin or dapagliflozin with empagliflozin for a composite outcome (myocardial infarction [MI] or stroke), heart failure hospitalization, MI, stroke, all-cause death, and safety outcomes, including diabetic ketoacidosis (DKA), lower-limb amputation, bone fracture, severe urinary tract infection (UTI), and genital infection and whether effects differed by dosage or cardiovascular disease (CVD) history.

View Article and Find Full Text PDF

Background: Anterior glenoid bone defects significantly influence surgical outcomes in shoulder instability cases. Various measurement methods based on 3-dimensional computed tomography (3D-CT) have been developed. Recently, the simple linear formula method, which establishes a correlation between glenoid height and width, has emerged as a promising technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!