A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Randomized Trial of Polymer-Free Sirolimus- and Probucol-Eluting Stents Versus Durable Polymer Zotarolimus-Eluting Stents: 5-Year Results of the ISAR-TEST-5 Trial. | LitMetric

Objectives: The aim of this study was to evaluate the late clinical performance of a polymer-free sirolimus- and probucol-eluting stent compared with a new-generation durable polymer-based zotarolimus-eluting stent.

Background: It was previously shown that polymer-free sirolimus- and probucol-eluting stents were noninferior to zotarolimus-eluting stents at 12 months. However, long-term follow-up of these devices is critical to evaluate late comparative efficacy.

Methods: In a clinical trial with minimal exclusion criteria, 3,002 patients were randomly assigned to treatment with polymer-free sirolimus- and probucol-eluting stents versus zotarolimus-eluting stents. The primary endpoint was the combined incidence of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization.

Results: At 5 years, there was no difference in the incidence of the primary endpoint between sirolimus- and probucol-eluting stents and zotarolimus-eluting stents (23.8% vs. 24.2%, respectively; hazard ratio: 0.98; 95% confidence interval: 0.84 to 1.15; p = 0.80). The rates of the individual components of the primary endpoint were also comparable in both groups. The incidence of definite or probable stent thrombosis was low in both groups (1.3% vs. 1.6%, respectively; hazard ratio: 0.86; 95% confidence interval: 0.46 to 1.62; p = 0.64). The rates of any death, myocardial infarction, and revascularization were similar in both groups. Results were consistent across pre-specified subgroups of age, sex, diabetes, and vessel size.

Conclusions: Long-term outcomes of patients treated with polymer-free sirolimus- and probucol-eluting stents compared with a new-generation durable polymer-based zotarolimus-eluting stent were similar. Rates of stent thrombosis were low and comparable in both treatment groups, with few events beyond 12 months. (Efficacy Study of Rapamycin- vs. Zotarolimus-Eluting Stents to Reduce Coronary Restenosis [ISAR-TEST-5]; NCT00598533).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2016.01.009DOI Listing

Publication Analysis

Top Keywords

sirolimus- probucol-eluting
24
polymer-free sirolimus-
20
probucol-eluting stents
20
zotarolimus-eluting stents
20
primary endpoint
12
stents
10
stents versus
8
evaluate late
8
compared new-generation
8
new-generation durable
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!