Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Statement Of Problem: The esthetic appearance of anatomic-contour zirconia restorations is influenced by the shade of the coloring liquid and the optical properties of the luting cements. However, few studies are available on the effects of surface-finishing methods and luting cements on colored anatomic-contour zirconia restorations.
Purpose: The purpose of this in vitro study was to investigate the effects of surface finishing methods on the color distribution of colored anatomic-contour zirconia crowns before and after being cemented onto abutments.
Material And Methods: Implant-supported anatomic-contour zirconia premolar crowns were fabricated and immersed in A3-coloring liquid for 30 seconds. The colored zirconia crowns were separated into 3 groups according to the method of surface treatment: no treatment (N), polishing (P), and glazing (G). The zirconia crowns without coloring liquid application served as the control group. CIELab color coordinates were obtained, and color differences (ΔE) between shaded crowns were calculated with a spectrophotometer. The color stability of the crown before and after cement application was also investigated.
Results: Before cement application, the mean color difference between groups N and P was 2.85 ΔE units, whereas the mean ΔE value between groups N and G was 3.27. Mean ΔE values with and without cement application among groups ranged from 2.75 to 3.45 ΔE units.
Conclusions: The color appearance of the colored zirconia crowns was strongly influenced by the surface-finishing methods and luting cement application.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2015.12.012 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!