OBJECTIVE The objective of this study was to assess the incidence of postoperative hardware infection following interventional (i)MRI-guided implantation of deep brain stimulation (DBS) electrodes in a diagnostic MRI scanner. METHODS A diagnostic 1.5-T MRI scanner was used over a 10-year period to implant DBS electrodes for movement disorders. The MRI suite did not meet operating room standards with respect to airflow and air filtration but was prepared and used with conventional sterile procedures by an experienced surgical team. Deep brain stimulation leads were implanted while the patient was in the magnet, and patients returned 1-3 weeks later to undergo placement of the implantable pulse generator (IPG) and extender wire in a conventional operating room. Surgical site infections requiring the removal of part or all of the DBS system within 6 months of implantation were scored as postoperative hardware infections in a prospective database. RESULTS During the 10-year study period, the authors performed 164 iMRI-guided surgical procedures in which 272 electrodes were implanted. Patients ranged in age from 7 to 78 years, and an overall infection rate of 3.6% was found. Bacterial cultures indicated Staphylococcus epidermis (3 cases), methicillin-susceptible Staphylococcus aureus (2 cases), or Propionibacterium sp. (1 case). A change in sterile practice occurred after the first 10 patients, leading to a reduction in the infection rate to 2.6% (4 cases in 154 procedures) over the remainder of the procedures. Of the 4 infections in this patient subset, all occurred at the IPG site. CONCLUSIONS Interventional MRI-guided DBS implantation can be performed in a diagnostic MRI suite with an infection risk comparable to that reported for traditional surgical placement techniques provided that sterile procedures, similar to those used in a regular operating room, are practiced.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2015.7.JNS15750DOI Listing

Publication Analysis

Top Keywords

deep brain
12
diagnostic mri
12
mri suite
12
operating room
12
suite infection
8
10-year period
8
postoperative hardware
8
brain stimulation
8
dbs electrodes
8
mri scanner
8

Similar Publications

Objective: The aim of this study was to evaluate outcomes of deep brain stimulation (DBS) for Meige syndrome, compare the efficacy of globus pallidus internus (GPi) and subthalamic nucleus (STN) as targets, and identify potential outcome predictors.

Methods: The PubMed, Embase, and Web of Science databases were systematically searched to collect individual data from patients with Meige syndrome receiving DBS. Outcomes were assessed using the Burke-Fahn-Marsden Dystonia Rating Scale motor (BFMDRS-M) and disability (BFMDRS-D) scores.

View Article and Find Full Text PDF

Nanophotonic inspection of deep-subwavelength integrated optoelectronic chips.

Sci Adv

January 2025

Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou 510632, China.

Artificial nanostructures with ultrafine and deep-subwavelength features have emerged as a paradigm-shifting platform to advanced light-field management, becoming key building blocks for high-performance integrated optoelectronics and flat optics. However, direct optical inspection of integrated chips remains a missing metrology gap that hinders quick feedback between design and fabrications. Here, we demonstrate that photothermal nonlinear scattering microscopy can be used for direct imaging and resolving of integrated optoelectronic chips beyond the diffraction limit.

View Article and Find Full Text PDF

Time series segmentation for recognition of epileptiform patterns recorded via microelectrode arrays in vitro.

PLoS One

January 2025

Instituto de Microelectrónica de Sevilla (IMSE-CNM), Consejo Superior de Investigaciones Científicas (CSIC) and Universidad de Sevilla, Sevilla, Spain.

Epilepsy is a prevalent neurological disorder that affects approximately 1% of the global population. Approximately 30-40% of patients respond poorly to antiepileptic medications, leading to a significant negative impact on their quality of life. Closed-loop deep brain stimulation (DBS) is a promising treatment for individuals who do not respond to medical therapy.

View Article and Find Full Text PDF

Introduction: While cerebral amyloid angiopathy is likely responsible for intracerebral hemorrhage (ICH) occurring in superficial (grey matter, vermis) cerebellar locations, it is unclear whether hypertensive arteriopathy (HA), the other major cerebral small vessel disease (cSVD), is associated with cerebellar ICH (cICH) in deep (white matter, deep nuclei, cerebellar peduncle) regions. We tested the hypothesis that HA-associated neuroimaging markers are significantly associated with deep cICH compared to superficial cICH.

Patients And Methods: Brain MRI scans from consecutive non-traumatic cICH patients admitted to a referral center were analyzed for cSVD markers.

View Article and Find Full Text PDF

Background: The internal venous system of the brain is a crucial anatomical landmark during accesses to the third ventricle through the foramen of Monro. Many classifications based on radiological assessment of the system have been developed, but they tend to be descriptive and do not highlight favorable anatomical variants. The aim of our study was to create a system based on morphometric measurements to facilitate preoperative decision-making regarding access to third ventricle tumors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!