Bisphenol A (BPA) is an endocrine disruptor found in food containers and plastic beverages and also in medical devices such as dialyzers. The aim of this study is while taking into account the BPA originating in medical devices and the water used in dialysate production, to provide the first published investigation of overall potential exposure to BPA during hemodialysis treatment in patients suffering from end-stage renal disease. BPA concentration in water (at each step of purification treatment) and in dialysate and BPA leaching from dialyzers were determined using solid-phase extraction coupled to ultra-high-performance-liquid chromatography tandem mass spectrometry. We have corroborated the hypothesis that a significant amount of BPA may migrate from dialyzers and also demonstrated that BPA is provided by the water used in dialysate production (8.0±5.2ngL(-1) on average) and by dialysis machine and dialysate cartridges, leading to dialysate contamination of 22.7±15.6ngL(-1) on average. Taking into account all the sources of BPA contamination that may come into play during a hemodialysis session, the highest exposure could reach an estimated 140ng/kg b.w./day for hemodialyzed patients, directly available for systemic exposure. Finally, BPA contamination should be taken into account as concerns both the medical devices commonly used in hemodialysis and purified water production systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijpharm.2016.03.003 | DOI Listing |
JMIR AI
January 2025
Faculty of Social Science, Ruhr University Bochum, Bochum, Germany.
Background: Conversational agents (CAs) are finding increasing application in health and social care, not least due to their growing use in the home. Recent developments in artificial intelligence, machine learning, and natural language processing have enabled a variety of new uses for CAs. One type of CA that has received increasing attention recently is smart speakers.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA, USA.
Purpose: To compare the assessment of clinically relevant retinal and choroidal lesions as well as optic nerve pathologies using a novel three-wavelength ultra-widefield (UWF) scanning laser ophthalmoscope with established retinal imaging techniques for ophthalmoscopic imaging.
Methods: Eighty eyes with a variety of retinal and choroidal lesions were assessed on the same time point using Topcon color fundus photography (CFP) montage, Optos red/green (RG), Heidelberg SPECTRALIS MultiColor 55-color montage (MCI), and novel Optos red/green/blue (RGB). Paired images of the optic nerve, retinal, or choroidal lesions were initially diagnosed based on CFP imaging.
Anesth Analg
February 2025
From the Department of Surgical Specialties and Anesthesiology of São Paulo State University (UNESP), Medical School, Botucatu, Brazil.
Background: Proficiency in endotracheal intubation (ETI) is essential for medical professionals and its training should start at medical schools; however, large caseload may be required before achieving an acceptable success rate with direct laryngoscopy. Video laryngoscopy has proven to be an easier alternative for intubation with a faster learning curve, but its availability in medical training may be an issue due to its high market prices. We devised a low-cost 3-dimensionally printed video laryngoscope (3DVL) and performed a randomized trial to evaluate if the intubation success rate on the first attempt with this device is noninferior to a standard commercially available video laryngoscope (STVL).
View Article and Find Full Text PDFAnesth Analg
February 2025
Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.
Background: Several health care networks have fully adopted second-generation supraglottic airway (SGA) i-gel. Real-world evidence of enhanced patient safety after such practice change is lacking. We hypothesized that the implementation of i-gel compared to the previous LMA®-Unique™ would be associated with a lower risk of airway-related safety events.
View Article and Find Full Text PDFJ Mater Sci Mater Med
January 2025
Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.
Bone cement is commonly utilized to secure prosthetic joints in the body because of its robust fixation, stability, biocompatibility, and immediate load-bearing capability. However, issues such as loosening, leakage, and insufficient bioactivity can lead to its failure. Therefore, improving its mechanical, physical, and biological properties is crucial for enhancing its efficiency.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!