Objective: Evaluate the effects of supplemental fixation elements on the mechanical properties of a single ring circular fixator construct.
Study Design: In vitro mechanical testing.
Sample Population: Five construct configurations (six replicates of each configuration) were used to stabilize a 1.6 cm diameter Delrin rod bone model.
Methods: Constructs were assembled using 66 mm complete rings, 1.6 mm olive wires, and 3.2 mm diameter half-pins. Construct configurations tested were a base single ring construct, constructs with 1 supplemental drop wire or constructs with 1, 2, or 3 supplemental half-pins. Constructs were loaded in axial compression, caudocranial and mediolateral bending, and torsion. Strain was measured in individual fixation elements during axial loading.
Results: A supplemental drop wire or half-pin significantly increased bending and torsional stiffness. The supplemental half-pin increased caudocranial stiffness significantly more than placing a drop wire. Placing a 2nd or 3rd pin afforded significantly greater increases in construct stiffness in all modes of loading, with 3 half-pin constructs having significantly greater axial and caudocranial stiffness than 2 half-pin constructs. Placing a single supplemental pin induced cantilever bending resulting in angular displacement of the Delrin rod during axial loading and high strain in both the fixation wire secured distal to the ring and the pin. Supplemental half-pins incrementally reduced strain in all fixation elements and resulted in linear displacement of the Delrin rod during axial loading.
Conclusion: If using supplemental half-pins as fixation elements, insertion of 2 or 3 pins is preferred over a single pin.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vsu.12467 | DOI Listing |
Injury
December 2024
Golden Jubilee Medical Center, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Background: Severe metaphyseal comminution and sizable bone defect of the distal femur are high risks of fixation failure. To date, no exact magnitude of comminution and bone loss is determined as an indication for augmentation of fixation construct. The present study aimed to investigate the influence of metaphyseal gap width, working length, and screw distribution on the stability of the fixation construct.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Illinois Institute of Technology, Chicago, IL, USA.
Background: Elevated iron in brain is a source of free radicals that causes oxidative stress which has been linked to neuropathologies and cognitive impairment among older adults. The aim of this study was to investigate the association of iron levels with transverse relaxation rate, R2, and white matter hyperintensities (WMH), independent of the effects of other metals and age-related neuropathologies.
Method: Cerebral hemispheres from 437 older adults participating in the Rush Memory and Aging Project study (Table 1) were imaged ex-vivo using 3T MRI scanners.
J Clin Orthop Trauma
November 2024
Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India, 249203.
Orthopedic surgery and traumatology necessitate cost-effective approaches that can be replicated across multiple venues. Finite Element (FE) simulation models have evolved as a solution, allowing for consistent investigations into biomechanical systems. Finite Element Analysis (FEA), which began in the 1950s aviation industry, has since expanded into orthopedics.
View Article and Find Full Text PDFNPJ Biofilms Microbiomes
January 2025
Department of Biology, University of Padua, via U. Bassi 58/b, 35131, Padova, Italy.
Biomethanation is a crucial process occurring in natural and engineered systems which can reduce carbon dioxide to methane impacting the global carbon cycle. However, little is known about the effect of on-and-off gaseous provision and micronutrients on bioconversion. Here, anaerobic microbiomes underwent intermittent feeding with incremental starvations and selective metal supplementation to assess the impact of hydrogen and carbon dioxide availability on microbial physiology.
View Article and Find Full Text PDFInt Dent J
January 2025
Department of Prosthodontics, Dalian Stomatological Hospital, Dalian, China. Electronic address:
Introduction And Aims: Implantation of the posterior maxilla with insufficient bone height faces challenges. Studies have shown that the use of ultrashort implants can avoid additional damage. This finite element analysis study aimed to evaluate the impacts of different lengths of ultrashort implants and three surgical approaches on stress, strain, and displacement in the posterior maxilla with varying bone heights.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!