Comparison of Disinfection Procedures on the Catheter Adapter-Transfer Set Junction.

Perit Dial Int

Global Medical Affairs, Baxter Healthcare Corporation, One Baxter Parkway, Deerfield, IL 60015, USA.

Published: January 2017

Peritonitis is a significant complication of peritoneal dialysis (PD), contributing to mortality and technique failure. Suboptimal disinfection and/or a loose connection at the catheter adapter-transfer set junction are forms of touch contamination that can compromise the integrity of the sterile fluid path and lead to peritonitis. Proper use of the right disinfectants for connections at the PD catheter adapter-transfer set interface can help eliminate bacteria at surface interfaces, secure connections, and prevent bacteria from entering into the sterile fluid pathway. Three studies were conducted to assess the antibacterial effects of various disinfecting agents and procedures, and ensuing security of the catheter adapter-transfer set junction. An open-soak disinfection procedure with 10% povidone iodine improves disinfection and tightness/security of catheter adapter-transfer set connection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4803372PMC
http://dx.doi.org/10.3747/pdi.2014.00319DOI Listing

Publication Analysis

Top Keywords

catheter adapter-transfer
20
adapter-transfer set
20
set junction
12
sterile fluid
8
catheter
5
adapter-transfer
5
set
5
comparison disinfection
4
disinfection procedures
4
procedures catheter
4

Similar Publications

Comparison of Disinfection Procedures on the Catheter Adapter-Transfer Set Junction.

Perit Dial Int

January 2017

Global Medical Affairs, Baxter Healthcare Corporation, One Baxter Parkway, Deerfield, IL 60015, USA.

Peritonitis is a significant complication of peritoneal dialysis (PD), contributing to mortality and technique failure. Suboptimal disinfection and/or a loose connection at the catheter adapter-transfer set junction are forms of touch contamination that can compromise the integrity of the sterile fluid path and lead to peritonitis. Proper use of the right disinfectants for connections at the PD catheter adapter-transfer set interface can help eliminate bacteria at surface interfaces, secure connections, and prevent bacteria from entering into the sterile fluid pathway.

View Article and Find Full Text PDF

The purpose of this in vitro study was to evaluate the effectiveness of continuous ambulatory peritoneal dialysis (CAPD) procedures. Four procedures to disinfect the catheter adapter/transfer set connection were compared in vitro using a mock sterile CAPD system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!