Background: Constrained liners are used as part of a salvage procedure to provide stability for patients at high risk for dislocation after a total hip arthroplasty. However, no recent studies exist highlighting their effectiveness and/or limitations.
Method: This prospective review included 166 consecutive hip arthroplasties, either primary (27%) or revision (73%), with a unique design of a constrained liner: Lefèvre retentive cup. There were 113 females (69%), and the average age at index surgery was 75.9 years (range, 35-94). The mean follow-up was 6.2 years (range, 0.3-11).
Results: Twenty patients had a reoperation; 10 for infection (4 acute and 6 chronic joint infection) and 10 for cup failure (5 fixation failure, 3 aseptic loosening, and 2 dislocation). Ten-year survivals for cup revision were 89% (CI, 83-94) and 92% (CI, 89-97) for all revision and revision for noninfectious reasons, respectively. When solely evaluating for dislocation, the survival at 10 years was 99% (CI, 97-100). Considering primary and revision cases, 10-year survivals cup revision for aseptic reasons were 92.4% (CI, 84-100) and 92.5% (CI, 87-98), respectively.
Conclusions: The Lefèvre retentive cup demonstrated excellent 10-year's survivorship. With the rate of aseptic loosening around 2% and a dislocation rate around 1%, the cup is as effective as other available devices and is therefore a cost-effective tool to reduce the risk of dislocation in at-risk patients undergoing hip arthroplasty.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2016.02.031 | DOI Listing |
J Orthop Case Rep
January 2025
Department of Orthopaedics, Bombay Hospital, Mumbai, Maharashtra, India.
Introduction: The occurrence of non-traumatic bilateral femoral neck fractures is exceedingly rare, and their manifestation subsequent to an epileptic attack is an uncommon entity with very few cases reported globally.
Case Report: We present the positive outcome of a 68-year-old man who underwent staged bilateral constrained total hip arthroplasty following a fracture resulting from a generalized seizure. This unconventional decision was justified based on several factors, including fracture pattern, bone quality, seizure history, and advanced tribology.
Life (Basel)
November 2024
Sezione di Chirurgia Protesica ad Indirizzo Robotico-Unità di Traumatologia dello Sport, Ortopedia e Traumatologia, Fondazione Poliambulanza, 25124 Brescia, Italy.
Knee arthroplasty, commonly performed to treat osteoarthritis, necessitates precise surgical techniques for optimal outcomes. The introduction of systems such as the Persona Knee System (Zimmer Biomet, Warsaw, IN, USA) has revolutionized knee arthroplasty, promising enhanced precision and better patient outcomes. This study investigates the application of robotic planning specifically in knee prosthetic surgeries, with a focus on Persona Knee System prostheses.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
December 2024
Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia Dello Sport, UOC Ortopedia e Traumatologia, Brescia, Italy.
Purpose: The application of robotics in revision arthroplasty particularly from unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA), is underexplored. The purpose of this study is to describe the surgical technique of an imageless robotic system used in the revision of UKA to TKA and to evaluate short- to mid-term outcomes.
Methods: This prospective study includes 35 patients treated from May 2020 to July 2023.
J Orthop Case Rep
December 2024
Department of Orthopaedics, Seth GS Medical College and KEM Hospital, Mumbai, Maharashtra, India.
Introduction: Dual mobility (DM) total hip replacement (THR) features an acetabular component with an unconstrained tripolar build which ensures a greater range of motion without provoking any dislocation.We report three cases with extremes of surgical misadventure where we carried out a revision arthroplasty with a DM cup. The causes of the failure of the primary arthroplasty were multifactorial, even individually, and ranged from instability due to component malposition, trochanteric fracture, intrapelvic prosthesis protrusion, etc.
View Article and Find Full Text PDFHSS J
March 2024
Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Introduction: Instability after total knee arthroplasty (TKA) remains a leading cause of revision TKA and can lead to patient dissatisfaction. While many companies have developed midlevel constrained (MLC) polyethylene inserts in primary TKAs, there is little data on their outcomes.
Purpose: We sought to analyze short-term outcomes including survivorship, rates of manipulation under anesthesia (MUA), and improvements in patient-reported outcome measures (PROMs) preoperatively to postoperatively in one design of MLC TKA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!